%0 Journal Article %T Modelaci車n f赤sica del flujo de acero en un distribuidor de colada continua equipado con un inhibidor de turbulencia y una cortina de gas %A P谷rez-Labra %A M. %A D赤az-Cruz %A M. %A Palafox-Ramos %A J. %A 芍vila-D芍vila %A E. O. %J Revista de Metalurgia %D 2005 %I Consejo Superior de Investigaciones Cient赤ficas %X A 2/5 scale model with a transparent plastic sheet was built based on Froude criterion in which eight cases were studied by PIV technique, maintaining a constant gas flow rate of 596 ml/min and only varying the gas curtain position. The results permitted to get Residence Time Distribution (RTD) curves, and from the data processing it was found that combining Turbulence Inhibitor (TI) with the adequate gas curtain position it is enhanced the plug volume. The case VII presented the best results increasing the plug volume in 131.85 % in comparison with the de case IV which was taken as the reference one Usando el n迆mero de Froude como criterio de dise o se construy車 un modelo de distribuidor, en acr赤lico, a 2/5 de la escala real, en el cual, ocho casos propuestos se estudiaron mediante la t谷cnica PIV, manteniendo un flujo de gas constante de 596 ml/min y variando, solamente, la posici車n de la cortina de gas. Los resultados permitieron obtener curvas de distribuci車n de tiempos de residencia (RTD) y, del procesamiento de los datos, se hall車 que la combinaci車n del inhibidor de turbulencia (IT) con la adecuada posici車n de la cortina de gas present車 el mas alto volumen pist車n. El caso VII present車 los mejores resultados, incrementando el volumen pist車n en 131,85 % en comparaci車n con el caso IV, que fue tomado como referencia. %K Inclusion %K tundish %K PIV %K gas curtain %K RTD %K turbulence inhibitor %K Inclusi車n %K distribuidor %K PIV %K cortina de gas %K RTD %K inhibidor de turbulencia %U http://revistademetalurgia.revistas.csic.es/index.php/revistademetalurgia/article/view/232/230