%0 Journal Article %T Development of a Distribution System for Measuring Nozzle Integrative Parameters %A Xin-yu XUE %A Jian LIANG %A Ping-zeng LIU %A Yu-bin LAN %J Advances in Natural Science %D 2010 %I %R 10.3968/924 %X The experimental system used in this study was equipped with sensors and computer-controlled processing technology. This system was used in the measurement of major performance parameters such as pressure, flux, spray angle, spray distribution character of the nozzle and its integrative performance parameter. It could also achieve precise and synchronous measurements and process multiple parameters. Measuring position of a single nozzle was also available for three-dimensional adjustment by nozzle transmission frame. The boom could achieve two-dimensional precision adjustment. Fluid power supply system could ensure the accurate measurement of nozzle flow between 50~15000 ml/min. The control system consisted of a PC, a CCD image acquisition system, data acquisition cards, sensors, and single chip microcomputer. The spray angle was measured by image processing technique. Data fusion technology was used to improve the precise measurement of spray angle. Neural network technology was used to improve the precision and speed of the system. The results showed that it is promising for using this system for measuring nozzle integrative parameter. Keywords: Nozzle; performance test; image processing; and neural network %K Nozzle %K performance test %K image processing %K and neural network %U http://cscanada.net/index.php/ans/article/view/924