%0 Journal Article %T Estimaci車n del t赤tulo de anticuerpos IgG a Adenovirus utilizando una curva patr車n y un ensayo de ultramicroELISA indirecto %A JOSE LAFERTE %A CLARA SAVON %A ANGEL GOYENECHEA %A VALEXIS VAZQUEZ %J Revista Cubana de Medicina Tropical %D 1996 %I Centro Nacional de Informaci車n de Ciencias M谷dicas %X Se logr車 normalizar un procedimiento que combinaba un ensayo de ultramicroELISA indirecto con una curva patr車n y que permiti車 estimar el t赤tulo de anticuerpos IgG a Adenovirus en muestras de suero humano utilizando una sola diluci車n de 谷stos. Bas芍ndose en el t赤tulo a punto final previamente determinado para un panel de 117 muestras de suero, se seleccionaron 90 de 谷stas (r2 = 0,98) para construir 4 curvas patrones que relacionaron el logaritmo natural de las respuestas de fluorescencia y el logaritmo natural del t赤tulo a punto final para un rango amplio de diluciones del suero (1:40 hastra 1:320). Se seleccion車 la curva correspondiente a la diluci車n 1:40 del suero (r2 = 0,81), la cual posibilit車 una 車ptima utilizaci車n de los accesorios dise ados para la manipulaci車n de los vol迆menes en el rango ultramicro y, por tanto, la automatizaci車n de todo el procedimiento. Los resultados obtenidos con respecto a la t谷cnica de fijaci車n del complemento (100 % de sensibilidad y 97,3 % de especificidad) respaldan la utiizaci車n de este m谷todo como una herramienta complementaria en la ejecuci車n de estudios seroepidemiol車gicos a gran escala y con fines diagn車sticos. It was possible to standardize a procedure which combined an indirect microELISA assay with a standard curve and that allowed to estimate the titre of IgG antibodies to Adenovirus in samples of human serum, using only one dilution of these. Based on the end-point titre previously determined for a panel of 117 serum samples, we selected 90 of these samples (r2 = 0,98) to build 4 standard curves that related the natural logarithm of the fluorescence responses to the natural logarithm of the end-point titre for a wide range of serum dilutions (1:40=1:320). It was selected the curve corresponding to serum dilution 1:40 (r2 = 0,81), which made possible an optium utilization of those accessories designed to handle the volumes in the ultramicro range and, therefore, the automation of the whole procedure. The results obtained as regards the complement fixation test (100 % of sensitivity and 97,3 % of specificity) support the use of this method in our laboratory as a complementary tool to carry out seroepidemilogical studies on a large scale and with diagnostic ends. %K IGG %K ANTICUERPOS ANTIIDIOTIPICOS %K ADENOVIRUS HUMANO %K ELISA %K TESTS DE FIJACION DE COMPLEMENTO %K ANALISIS DE REGRESION %K IGG %K ANTIBODIES %K ANTIIDIOTYPIC %K ADENOVIRUSES %K HUMAN %K ENZIME-LINKED IMMUNOSORBENT ASSAY %K COMPLEMENT FIXATION TEST %K REGRESSION ANALYSIS %U http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0375-07601996000200006