%0 Journal Article %T Aplicaci車n de un m谷todo alternativo al conteo en c芍mara de Neubauer para determinar la concentraci車n de Trichomonas vaginalis %A Alfredo Meneses Marcel %A L芍zara Rojas %A Sergio Sifontes Rodr赤guez %A Yamil谷 L車pez %J Revista Cubana de Medicina Tropical %D 2001 %I Centro Nacional de Informaci車n de Ciencias M谷dicas %X Se demostr車 que existe relaci車n entre la concentraci車n celular y la lectura de los par芍sitos en un lector de ELISA. Se determin車 que la absorbancia tiene valores significativos en las longitudes de onda del rango visible y se escogi車 la longitud de onda m赤nima posible (450 nm) para garantizar un m芍ximo de sensibilidad. Pudo comprobarse que ocurre un aumento significativo de la absorbancia (p<0,001) despu谷s de llenada la placa, que se estabiliza en el intervalo de 40 min hasta 4 h. Al aplicar 100, 150, 200 車 300 米L por pozo de las diferentes concentraciones de c谷lulas se demostr車 que el volumen 車ptimo era de 150 米L, se obtuvo un r2 = 0,9986, y resultaron altamente significativos el coeficiente de correlaci車n (p<0,001) y la pendiente (p<0,001). En el intervalo de 5 x 104 a 1,5 x 107 c谷lulas/mL se obtuvo un coeficiente de variaci車n medio de 1,75 % (0,25-3,17 %). En estas condiciones el l赤mite de cuantificaci車n fue de 5,14 x 104 c谷lulas/mL. Por 迆ltimo se demostr車 que hubo significaci車n de la correlaci車n entre el conteo en c芍mara de Neubauer y la densidad 車ptica. It was demonstrated that there is a relation of cell concentration with the parasite reading in an ELISA reader. It was determined that absorbance showed significant values in wavelengths of visible range and the possible minimum wavelength (450 nm)was chosen to guarantee the maximum sensitivity. Likewise, it was confirmed that absorbance significantly increased (p<0.001) after the plate was filled up, it stabilized in the 40m-2h time interval when applying 100, 150, 200 or 300 ml per well of the various cell concentrations, it was proved that the optimum volume was 150 ml, a r2= 0,9986 was reached, and the coefficient of correction(p<0,001) and the gradient(p<0,001)were highly significant. In the 5 x 104 to 1.5 x 107 cell/mL interval, there was an average variation coefficient of 1.75% (0.25-3.17%). Under these conditions, the quantification limit was 5,14 x 104 cell/mL. Finally, it was shown that the correlation of counting in Neubauer chamber and optical density was significant. %K CAMARAS DE DIFUSION DE CULTIVOS %K TRICHOMONAS VAGINALIS %K TRICHOMONAS VAGINALIS %K TESTS DE ELISA %K DIFFUSION CHAMBERS %K CULTURE %K TRICHOMONAS VAGINALIS %K TRICHOMONAS VAGINALIS %K ENZYME-LINKED IMMUNOSORBENT ASSAYS %U http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0375-07602001000300006