%0 Journal Article %T Validaci車n de la t谷cnica de determinaci車n del nitr車geno am赤nico al trofin en su forma l赤quida Validation of the amino nitrogen determination technique to trophin in its liquid form %A Maritza Gonz芍lez P谷rez %A Yunier Dom赤nguez Reyes %A Yuriam Reyes Peˋa %A Ra迆l Gonz芍lez Hern芍ndez %J Revista Cubana de Farmacia %D 2008 %I ECIMED %X El presente trabajo tuvo como objetivo la validaci車n de la t谷cnica de determinaci車n del nitr車geno por el m谷todo de titulaci車n, la que se emplea en la cuantificaci車n de este componente en el antin谷mico y reconstituyente trofin. Se prepar車 una curva patr車n con un medio de cultivo de concentraci車n de nitr車geno am赤nico conocida para determinar la linealidad del patr車n, y se compar車 con el de la muestra mediante un an芍lisis de regresi車n. Se realizaron los estudios de exactitud donde no existieron diferencias significativas entre R y el 100 % para p > 0,05; en la repetibilidad se cumpli車 que el coeficiente de variaci車n es menor que el 5 %; en la especificidad no se encontraron diferencias significativas para una p > 0,05 entre la sumatoria del nitr車geno am赤nico de la mezcla de las materias primas y del trofin; en la precisi車n intermedia result車 que el coeficiente de variaci車n es menor que el 10 % y en cuanto al rango de ensayo se cumpli車 para las concentraciones de nitr車geno am赤nico 3 0,07 que es el rango de trabajo de la especificaci車n de calidad para el trofin The objective of this paper was to validate the nitrogen determination technique by the titering method, which is used in the quantification of this component in the antianemic and tonic trophin. A pattern curve was prepared with a known concentration culture medium of amino nitrogen to determine the linearity of the pattern and it was compared with that of the sample by regression analysis. Accuracy studies were conducted and no significant differences were found between R and the 100 % for S p > 0.05; in the repeatability, it was observed that the coefficient of variation was lower that 5 %; whereas in the specificity no marked differences were detected for p > 0.05 between the addition of the amino nitrogen of the mixture of raw materials and trophin. The variation coefficient was under 10 % in the intermediate precision. As regards the assay range, the amino nitrogen concentrations were 0.07, which is the working range of the quality specification for trophin %K Validaci車n %K nitr車geno am赤nico %K trofin %K Validation %K amino nitrogen %K trophin %U http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0034-75152008000100003