%0 Journal Article %T Algorithmic processing of pressure waveforms to facilitate estimation of cardiac elastance %A David Stevenson %A James Revie %A J. Geoffrey Chase %A Christopher E Hann %A Geoffrey M Shaw %A Bernard Lambermont %A Alexandre Ghuysen %A Philippe Kolh %A Thomas Desaive %J BioMedical Engineering OnLine %D 2012 %I BioMed Central %R 10.1186/1475-925x-11-28 %X A shear transform is developed in order to help locate information in the pressure waveforms. This transform turns difficult to locate corners into easy to locate maximum or minimum points as well as providing error correction.The method located all points on 87 out of 88 waveforms for Ppa, to within the sampling frequency. For Pao, out of 616 total points, 605 were found within 1%, 5 within 5%, 4 within 10% and 2 within 20%.The presented method provides a robust, accurate and dysfunction-independent way to locate points on the aortic and pulmonary artery pressure waveforms, allowing the non-invasive estimation of the left and right cardiac elastance. %U http://www.biomedical-engineering-online.com/content/11/1/28/abstract