%0 Journal Article %T Comparison of superior vena cava and femoroiliac vein pressure according to intra-abdominal pressure %A Hafid Ait-Oufella %A Pierre-Yves Boelle %A Arnaud Galbois %A Jean-luc Baudel %A Dimitri Margetis %A Mikael Alves %A Georges Offenstadt %A Eric Maury %A Bertrand Guidet %J Annals of Intensive Care %D 2012 %I Springer %R 10.1186/2110-5820-2-21 %X We conducted a prospective, observational study in a tertiary teaching hospital. We enrolled patients who had indwelling catheters in both superior vena cava (double lumen catheter) and femoroiliac veins (dialysis catheter) and into the bladder. Pressures were measured from all the sites, CVP, femoroiliac venous pressure (FIVP), and intra-abdominal pressure.A total of 30 patients were enrolled (age 62£¿¡À£¿14£¿years; SAPS II 62 (52¨C76)). Fifty complete sets of measurements were performed. All of the studied patients were mechanically ventilated (PEP 3 cmH20 (2¨C5)). We observed that the concordance between CVP and FIVP decreased when intra-abdominal pressure increased. We identified 14£¿mmHg as the best intra-abdominal pressure cutoff, and we found that CVP and FIVP were significantly more in agreement below this threshold than above (94% versus 50%, P£¿=£¿0.002).We reported that intra-abdominal pressure affected agreement between CVP measurements from catheter placed in superior vena cava and catheters placed in the femoroiliac vein. Agreement was excellent when intra-abdominal pressure was below 14£¿mmHg. %K Intensive unit care %K Central venous pressure %K Superior vena cava %K Femoroiliac vena %K Intra-abdominal pressure %U http://www.annalsofintensivecare.com/content/2/1/21/abstract