%0 Journal Article %T Strategies of Miniaturised Reference Electrodes Integrated in a Silicon Based ¡°one chip¡± pH Sensor %A Anette Simonis %A Hans L¨¹th %A Joseph Wang %A J. Sch£¿ning %J Sensors %D 2003 %I MDPI AG %R 10.3390/s30900330 %X Different types of Ag/AgCl reference electrodes have been realised by means of thin- and thick-film technique. For inner electrolyte, KCl-containing membranes have been deposited and different coatings have been used to protect the reference electrode from a fast leaching out of KCl. The stability of the potential of the reference electrodes without KClcontaining membranes in 3 M KCl was about 7 hours for thin-film electrodes and up to 90 hours for thick-film electrodes. The reference electrodes with membrane were stable for more than two months. The thick-film reference electrode was integrated with a thin-film pH sensor onto one chip and the system pH sensor/reference electrode was investigated by means of capacitance/voltage (C/V) and constant capacitance (ConCap) mode. %K reference electrode %K thin-film technique %K thick-film technique %K ¡°one chip¡± sensor %K pH sensor %U http://www.mdpi.com/1424-8220/3/9/330