%0 Journal Article
%T Research on measurement method of slurry droplets carried by coal-fired flue gas after WFGD
脱硫后净烟气携带浆液量监测的实验研究
%A Pan Guang
%A Chang Jingcai
%A Ma Chunyuan
%A Dong Yong
%A Yan Jun
%A Chen Peng
%A
潘光
%A 常景彩
%A 马春元
%A 董勇
%A 闫君
%A 陈朋
%J 环境工程学报
%D 2011
%I
%X Slurry droplets carried by flue gas after WFGD would cause corrosion and blockage of the succeeding equipments, and affect residents in the surrounding. A revised method applicable to environmental monitoring was put forward combined with the relevant criterion to improve the accuracy of current means, and the factors such as sampling and analyzing were discussed at the same time. The results show that it was more precise and practicable than used ones, the detection limit of the modified method was 1.1 mg/Nm3, and had significant advancement for measuring slurry droplet of purified flue gas for environmental monitoring aspect.
%K 监测
%K 净烟气
%K 浆液液滴
%U http://www.alljournals.cn/get_abstract_url.aspx?pcid=3FF3ABA7486768130C3FF830376F43B398E0C97F0FF2DD53&cid=92E6F4267FD4CBCB51B1E49E014D8054&jid=3567BD61129AA59043F5DE01F8815DB5&aid=6F9043395C7244CC2F22454B56AEF93C&yid=9377ED8094509821&vid=94C357A881DFC066&iid=E158A972A605785F&sid=BE05E2A2B7E55AA9&eid=750AE535ABE3D62A&journal_id=1673-9108&journal_name=环境工程学报&referenced_num=0&reference_num=0