%0 Journal Article %T Effects of Influent Flow Distribution Ratio on Nitrogen Removal in Step-Feed A/O Process
流量分配对分段进水A/O工艺脱氮性能的影响 %A WANG Wei %A WANG Shu-ying %A SUN Ya-nan %A YIN Fang-fang %A PENG Yong-zhen %A
王伟 %A 王淑莹 %A 孙亚男 %A 殷芳芳 %A 彭永臻 %J 环境科学 %D 2009 %I %X In order to optimize the utilization of influent carbon source,a feeding pattern so-called "coefficient of influent flow rate" was adopted in a pilot-scale step-feed A/O process treating domestic wastewater.The effects of influent flow distribution ratio on nitrogen removal efficiency were investigated when the reactor was operated at different loading rates and COD/TKN ratio of 3,5,7,9,11,13,respectively.The experiment results indicated that the wasting of nitrification capacity occurred when high loading ... %K A/O
生活污水 %K 脱氮 %K 分段进水 %K 流量分配 %U http://www.alljournals.cn/get_abstract_url.aspx?pcid=3FF3ABA7486768130C3FF830376F43B398E0C97F0FF2DD53&cid=A7CA601309F5FED03C078BCE383971DC&jid=64CD0AA99DD39F69401C615B85F123EF&aid=82167474241C0A2541F1435D32439A4B&yid=DE12191FBD62783C&vid=340AC2BF8E7AB4FD&iid=CA4FD0336C81A37A&sid=6700D0D256586E73&eid=74011071555EB4E5&journal_id=0250-3301&journal_name=环境科学&referenced_num=0&reference_num=15