%0 Journal Article %T Effects of pH and CU~(2+) on the Detection of the Microcystin-LR Based on Fluorescence Immunoassay and Their Elimination
pH和铜离子对微囊藻毒素-LR荧光免疫检测的影响与消除 %A LONG Feng %A SHI Han-chang %A ZHU An-na %A HE Miao %A
龙峰 %A 施汉昌 %A 朱安娜 %A 何苗 %J 环境科学 %D 2009 %I %X The effects of pH and Cu 2+ on the detection of the Microcystin-LR based on evanescent wave all-fiber immunosensor (EWAI) and their elimination were studied. The experimental results indicated that both low pH and high pH greatly affected the immunoassay results of MC-LR. When pH was less than 6 or higher than 8,the fluorescence signals detected by immunosensor system obviously reduced with the decrease or increase of pH. While pH ranged from 6 to 8,IC 50 and the linear working range of MC-LR calculated fro... %K microcystin-LR %K Cu2+ %K fluorescence immunoassay %K evanescent wave %K fiber-optic immunosensor
微囊藻毒素-LR %K 铜离子 %K 荧光免疫检测 %K 倏逝波 %K 光纤免疫传感器 %U http://www.alljournals.cn/get_abstract_url.aspx?pcid=3FF3ABA7486768130C3FF830376F43B398E0C97F0FF2DD53&cid=A7CA601309F5FED03C078BCE383971DC&jid=64CD0AA99DD39F69401C615B85F123EF&aid=A7204C3D0C3435727B76DE2B519DF234&yid=DE12191FBD62783C&vid=340AC2BF8E7AB4FD&iid=DF92D298D3FF1E6E&sid=CF7717776B0449E1&eid=D3A55680A8B4A1DC&journal_id=0250-3301&journal_name=环境科学&referenced_num=0&reference_num=11