%0 Journal Article
%T The Monitoring System and the Analysis of Locating Theory for Pipeline Leakage Detection Based on Single Distributed Optical Fiber Sensor
单轴分布式光纤传感器管线泄漏探测方法及定位理论分析
%A The Key Laboratory for Optoelectronic Technology & Systems
%A Education Ministry of China
%A Chongqing University
%A Chongqing
%A The Unit of PLA
%A
谭靖
%A 陈伟民
%A 朱永
%A 王丁
%J 光子学报
%D 2006
%I
%X The pipeline leakage detecting and locating system based on Sagnac interferometer and distributed optical fiber technology has many advantages,such as the long monitoring range and the high precision in fault locating.In the prototype,the non-sensing fiber portion of the Sagnac ring must be shielded to avoid disturbance, which will restrict the application in actual monitoring system.To address this problem,a new optical configuration was put forward in this paper.It adopted one optical fiber line as sensing part instead of the optical fiber ring,and some necessary modifications were made to remove the effect of the fiber birefringence.A theoretical analysis of optical path and locating method were also given in this paper,which demonstrated the feasibility of pipeline intrusion (or leakage) detecting and locating by this system.
%K Pipeline
%K Leakage location
%K Optical fiber sensor
油气管线
%K 泄漏定位
%K 光纤传感器
%U http://www.alljournals.cn/get_abstract_url.aspx?pcid=6E709DC38FA1D09A4B578DD0906875B5B44D4D294832BB8E&cid=47EA7CFDDEBB28E0&jid=9F6139E34DAA109F9C104697BF49FC39&aid=BD228F75FE2CECCA&yid=37904DC365DD7266&vid=6209D9E8050195F5&iid=0B39A22176CE99FB&sid=CA5852BD1A173B3A&eid=FA89360EB995A8AD&journal_id=1004-4213&journal_name=光子学报&referenced_num=16&reference_num=16