%0 Journal Article %T Methods for Testing Sight-axis Consistency of Multi-sensor Photoelectric System
多传感器光电系统视轴一致性测试方法研究 %A XU Zhao-dong %A AN Shi-pu %A LIU Xin %A
许照东 %A 安世甫 %A 刘欣 %J 光子学报 %D 2007 %I %X Three kinds of methods for testing the sight axis consistency of wide-spectrum,multi-sensor photoelectric aiming and tracking system are introduced,i.e.,imaging paper,CCD and target.The main error source of each of the test method is also analyzed.By building some kind of platform for test.The sight-axis consistency of the same multi-sensor photoelectric system by using the methods of imaging paper,CCD and target respectively is analyed.The result shows that the test of sight-axis consistency with CCD method had a high(est) accuracy. %K Photoelectric system %K Sight-axis test %K Sight-axis consistency
光电系统 %K 视轴测试 %K 视轴一致性 %U http://www.alljournals.cn/get_abstract_url.aspx?pcid=6E709DC38FA1D09A4B578DD0906875B5B44D4D294832BB8E&cid=47EA7CFDDEBB28E0&jid=9F6139E34DAA109F9C104697BF49FC39&aid=E58AB31891A100DD7A0E5FD0D51E8B5D&yid=A732AF04DDA03BB3&vid=933658645952ED9F&iid=708DD6B15D2464E8&sid=8D601B5F3948DDF6&eid=A4F4D28C1A7C14B6&journal_id=1004-4213&journal_name=光子学报&referenced_num=0&reference_num=9