%X A focal length measurement method using inaccurate joint transform correlation technique is proposed.The joint power spectrum is recorded using lens of known focal length,and correlation spots are output by the lens to be measured.The correlation spots are recorded ,correlation spot interval is measured,and focal length can be calculated.The results show that the measurement precision is higher and the method can be potentially applied to focal length measurement automation.
%K Focal length measurement
%K Joint transform correlation
%K Inaccurate joint transform correlation
焦距测量
%K 联合相关变换
%K 非准确联合相关
%U http://www.alljournals.cn/get_abstract_url.aspx?pcid=6E709DC38FA1D09A4B578DD0906875B5B44D4D294832BB8E&cid=47EA7CFDDEBB28E0&jid=9F6139E34DAA109F9C104697BF49FC39&aid=230A68A2EF70D8E18CBE736D641D70C9&yid=67289AFF6305E306&vid=42425781F0B1C26E&iid=B31275AF3241DB2D&sid=08DDB398556FE547&eid=F58A98E9A761BF85&journal_id=1004-4213&journal_name=光子学报&referenced_num=0&reference_num=10