%T FAILURE ANALYSIS OF A TUBE SHEET OF CONDENSER
冷凝器管板失效分析
%A LIN Ping
%A YU Qiang
%A YUE Bin
%A ZHANG Dungen
%A
林萍
%A 俞强
%A 岳斌
%A 张敦艮
%J 腐蚀科学与防护技术
%D 2001
%I
%X Failure analysis has been made for a tube sheet of a condenser with X-ray diffractometer, scan electron microscope(SEM),optical microscope, and chemical analysis.Failure of the tube sheet was caused by sulphuric-acid dew corrosion.Measurements of improving are also proposed.
%K condenser
%K tube sheet
%K dew corrosion
%K sulphuric
%K acid
冷凝器
%K 管板
%K 露点腐蚀
%K 失效分析
%K 换热器
%K 硫酸
%U http://www.alljournals.cn/get_abstract_url.aspx?pcid=5B3AB970F71A803DEACDC0559115BFCF0A068CD97DD29835&cid=AB188D3B70B071C57EB64E395D864ECE&jid=9F6E6EC8BA5BB62698F6640073DDD6E1&aid=7F30BB640DC4058D&yid=14E7EF987E4155E6&vid=FC0714F8D2EB605D&iid=E158A972A605785F&sid=002786F01A86D891&eid=D537C66B6404FE57&journal_id=1002-6495&journal_name=腐蚀科学与防护技术&referenced_num=1&reference_num=19