王菊香 %A 王锡良 %A 申刚 %J 腐蚀科学与防护技术 %D 2002 %I %X An analysis was conducted on a failure case of the special circuit of the oxidant-fueling facility of an oxidant dispenser,which accured after a replacement of its engine.The results of analysis and simulation test show that this kind of failure may be due to deposition of corrosion products certain on parts of the fueling system so that to change the conductivity of the circuit.The corrosion is induced by a mis-connection of the two poles of battery to the system during the engine replacement.There with,some improvement suggestions are postulated by the author. %K red-fuming nitric acid %K probe %K electrolyte
电源极性 %K 氧化剂加注车 %K 红烟硝酸 %K 触针 %K 电解 %K 海防导弹 %K 蓄电池 %U http://www.alljournals.cn/get_abstract_url.aspx?pcid=5B3AB970F71A803DEACDC0559115BFCF0A068CD97DD29835&cid=AB188D3B70B071C57EB64E395D864ECE&jid=9F6E6EC8BA5BB62698F6640073DDD6E1&aid=746E53DD6A30CCEE&yid=C3ACC247184A22C1&vid=F3583C8E78166B9E&iid=E158A972A605785F&sid=FD7C952458BFB5D8&eid=6CCE24D86D03D083&journal_id=1002-6495&journal_name=腐蚀科学与防护技术&referenced_num=0&reference_num=3