%0 Journal Article %T A STUDY ON LOCATION OPTIMIZATION OF ANODE TO PIPE IN CATHODIC PROTECTION SYSTEMS
管道阴极保护体系阳极位置优化的研究 %A WENG Yongji %A ZHANG Yong %A LI Xiangyi %A
翁永基 %A 张勇 %A 李相怡 %J 腐蚀科学与防护技术 %D 1999 %I %X The optimization of anode location along pipe line was explored. According to the theory of electric field of stable currents, the following functions were studied: (A) the influence of anode location on the anodic resistance (medium circuit resistance) and on the potential of the junction field and on the potential distribution along the pipe. Based point to anode cable; (B) the influence of anode location on the anode electric field and on the potential distribution along the pipe line. Based on the ratio of components composing cathodic protection potential system, the anode distance (from 0 to ) were divided into three regions. The optimization of anode distance in short range region and in long range region was discussed in details. \= %K pipeline %K cathodic protection %K mathematical modeling %K anode %K optimization of anode location\=
管道 %K 阴极保护 %K 数学模型 %K 阳极 %K 位置优化 %U http://www.alljournals.cn/get_abstract_url.aspx?pcid=5B3AB970F71A803DEACDC0559115BFCF0A068CD97DD29835&cid=AB188D3B70B071C57EB64E395D864ECE&jid=9F6E6EC8BA5BB62698F6640073DDD6E1&aid=7CB12BD3B0C08F33&yid=B914830F5B1D1078&vid=708DD6B15D2464E8&iid=38B194292C032A66&sid=5E25104E99903E8A&eid=A8DE7703CC9E390F&journal_id=1002-6495&journal_name=腐蚀科学与防护技术&referenced_num=2&reference_num=3