%0 Journal Article
%T The Study of In-Orbit Calibration Accuracy of NOAA Satellite Infrared Sounder and Its Effect on Temperature Profile Retrievals
%A Dong Chaohu
%A Liu Quanhu
%A Li Guangqing
%A Zhang Fengying
%A
%J 大气科学进展
%D 1990
%I
%X The calibration accuracy of High Resolution Infrared Radiation Sounder Mod. 2 (H1RS / 2) on NOAA-10 sat-ellite is analyzed in this paper. The non-linear effect in the linear calibration curve induces a deviation of 1.5 degrees (k) of brightness temperature in the tenth channel (8.3 urn, water vapor absorption) of the HIRS / 2 and the non-linear effect affects the other channels to a different extent. Based on analyzing non-linearity in two-point calibration curve, a tri-point calibration equation is given. A numerical test of effects of the linear and non-linear calibration models on the accuracy of atmospheric temperature retrievals is carried out.
%U http://www.alljournals.cn/get_abstract_url.aspx?pcid=E62459D214FD64A3C8082E4ED1ABABED5711027BBBDDD35B&cid=28A2F569B2458C17&jid=5434AFBF6CB6E7E8D67733B541F211C7&aid=E47542F43A92AD28F0B2003CAC2BF626&yid=8D39DA2CB9F38FD0&vid=DF92D298D3FF1E6E&iid=0B39A22176CE99FB&sid=CC0ECB9C52F1B85F&eid=D5C73DEF4CF8FAF3&journal_id=0256-1530&journal_name=大气科学进展&referenced_num=0&reference_num=0