%0 Journal Article %T ANAYSIS OF TUBE LEAKAGE OF A PARTITION OVERHEATER
日照电厂2~#锅炉屏式过热器泄漏原因 %A WANG Sheng %A
王胜 %J 腐蚀科学与防护技术 %D 2008 %I %X The tube leakage of partition overheater of No.2 boiler in a power plant was studied by means of metallography,intergranular corrosion test and EDS.The results show that intergranular corrosion is found in the part between weldments 2# and 3# of the tube. %K partition tube %K intergranular corrosion %K leakage
屏式过热器 %K 晶间腐蚀 %K 泄漏 %U http://www.alljournals.cn/get_abstract_url.aspx?pcid=5B3AB970F71A803DEACDC0559115BFCF0A068CD97DD29835&cid=AB188D3B70B071C57EB64E395D864ECE&jid=9F6E6EC8BA5BB62698F6640073DDD6E1&aid=20FFD9F3F4B2F7793DFF2DAAB3FDD374&yid=67289AFF6305E306&vid=A04140E723CB732E&iid=38B194292C032A66&sid=1E41DF9426604740&eid=974CBB04624305A1&journal_id=1002-6495&journal_name=腐蚀科学与防护技术&referenced_num=0&reference_num=0