%0 Journal Article
%T A MICROWAVE SYSTEM FOR MEASURING HUMIDITY OF CLASTIC DIELECTRIC ON CONVEYER WITH PROGRAMMABLE COUNTER
用微处理器的随线式微波测湿系统
%A Huo Zhendi
%A Fu Shouchun
%A
火真棣
%A 伏寿椿
%J 电子与信息学报
%D 1986
%I
%X A sensitive linear sensor, which is suitable for ineasuring humidity of elastic dielectric on conveyer, is presented. A programmable counter is used to improve the measuring accuracy. The dynamic test of this system has been completed on the conveyer in Shanghai Coking Factory. The experimental results are in good agreement with the actual humidity of the coking coal.
%U http://www.alljournals.cn/get_abstract_url.aspx?pcid=5B3AB970F71A803DEACDC0559115BFCF0A068CD97DD29835&cid=1319827C0C74AAE8D654BEA21B7F54D3&jid=EFC0377B03BD8D0EF4BBB548AC5F739A&aid=1CC58458D4544457&yid=4E65715CCF57055A&vid=5D311CA918CA9A03&iid=E158A972A605785F&sid=69E4C201C13601F9&eid=11CEECA6DA9E4AC5&journal_id=1009-5896&journal_name=电子与信息学报&referenced_num=0&reference_num=4