%0 Journal Article
%T Measurements of AIM for Visible Wavelength Based on Individual Eye Model
%A WANG Wei
%A WANG Zhao-Qi
%A WANG Yan
%A ZUO Tong
%A ZHAO Kan-Xing
%A
王伟
%A 王肇圻
%A 王雁
%A 左彤
%A 赵堪兴
%J 中国物理快报
%D 2006
%I
%X We measure and calculate the aerial image modulation (AIM) of human retina for visible wavelengths based on the individual eye model. By employing the optical design software ZEMAX, we obtain the modulation transfer function (MTF) of human eye in visible wavelengths. Using CSV-1000 and VAF-1000, the contrast sensitivity function (CSF) and the visual acuity (VA) for the same eye are measured. Then the AIM of human retina could be acquired by the relations between MTF and CSF and between MTF and VA. The AIM of human retina is independent of MTF, and the values of AIM for normal eyes (without retina disease) are similar, so the assembly average for large numbers of normal eyes can be a standard AIM curve, which is helpful for the diagnosis of diseases in the retina system.
%K 42
%K 30
%K Va
%K 42
%K 66
%K Ew
个体人眼模型
%K 可见光
%K 波长
%K AIM
%U http://www.alljournals.cn/get_abstract_url.aspx?pcid=6E709DC38FA1D09A4B578DD0906875B5B44D4D294832BB8E&cid=47EA7CFDDEBB28E0&jid=E27DA92E19FE279A273627875A70D74D&aid=F761654E536C14CC06BB39CBC0534FA9&yid=37904DC365DD7266&vid=EA389574707BDED3&iid=59906B3B2830C2C5&sid=2E633E1945399CA7&eid=E40E84C3E1578338&journal_id=0256-307X&journal_name=中国物理快报&referenced_num=0&reference_num=13