%0 Journal Article
%T STUDY ON SAFETY FACTOR OF 3# DAM FOUNDATION OF LEFT POWER HOUSE OF THREE GORGES PROJECT USING SLICE JOINT ELEMENT
结构面按薄层单元模拟的三峡左厂3#坝段安全系数研究
%A Ren Jianxi
%A Li Chunguang
%A Ge Xiurun
%A
任建喜
%A 李春光 葛修润
%J 岩石力学与工程学报
%D 2004
%I
%X A 3D finite element model including 41 large structures and 5 faults based on the real geometry is established. The model is used to study the stability of 3# dam foundation of the left power house of the Three Georges Project and the failure mode of power house. A rule for estimating safety factor of dam foundation in terms of strength reservation is proposed based on the results of the 3D finite element analyses. For 3# dam foundation,the suggested safety factor is about 3.5 based on the computation results,which also confirms the safety of power house.
%K rock mechanics
%K 3D model based on real attitude
%K deep sliding
%K safety factor
%K dam foundation
岩石力学
%K 深层滑动
%K 安全系数
%K 坝基
%K 三维有限元模型
%U http://www.alljournals.cn/get_abstract_url.aspx?pcid=5B3AB970F71A803DEACDC0559115BFCF0A068CD97DD29835&cid=D3421FAA1A0A0F0C&jid=35E747D791A1346351AFB523B7FA35CB&aid=249193F3237D6784&yid=D0E58B75BFD8E51C&vid=EA389574707BDED3&iid=DF92D298D3FF1E6E&sid=63025EFC6CC49145&eid=AF41770817DB8958&journal_id=1000-6915&journal_name=岩石力学与工程学报&referenced_num=3&reference_num=11