%0 Journal Article %T Study of Compressible Flow Measurement based on Seven-Hole Probe
七孔探针可压缩流场测量研究 %A BAI Ya-lei %A MING Xiao %A DING Tao %A
白亚磊 %A 明晓 %A 丁涛 %J 实验力学 %D 2010 %I %X This paper presents a calibrating method of measuring relative flow velocity, flow angle, local total and static pressure for subsonic compressible flows using seven-hole probe. Seven-hole probe (SHP) is a device that can simultaneously measure the pressure and velocity of a steady flow, especially the parameters of compressible flow. However, the costly and time-consuming calibration impedes its extensive application. Study of calibration and measurement method for compressible flow was carried out using seven-hole probe (SHP) based on the data from numerical simulation. Results show that the accuracy of calibration fitting of flow angle is about 2%, the relative value of both total pressure and static pressure are less than 3%. These results are better than experimental calibration accuracy in the same situation. In practice, this method is used to replace or guide traditional experimental calibration method, it can save a lot of calibration time and cost, so that seven-hole probe measurement for subsonic compressible flow has become simple and feasible. %K seven-hole probe %K computational fluid dynamics %K compressible flow measurement %K numerical calibration
七孔探针 %K 计算流体力学 %K 可压缩流测量 %K 数值校准 %U http://www.alljournals.cn/get_abstract_url.aspx?pcid=6E709DC38FA1D09A4B578DD0906875B5B44D4D294832BB8E&cid=5D344E2AD54D14F8&jid=49067A0A0D864088C06A84AACB51A5B2&aid=8441EA268B18F029D8DD50A257A47A13&yid=140ECF96957D60B2&vid=C5154311167311FE&iid=B31275AF3241DB2D&sid=06DAE5E1DF7D0B6A&eid=B7DE0F3CA34DA149&journal_id=1001-4888&journal_name=实验力学&referenced_num=0&reference_num=0