%X A thermal model for concentrator solar cells based on energy conservation principles was designed. Under 400X concentration with no cooling aid, the cell temperature would get up to about 1200_C. Metal plates were used as heat sinks for cooling the system, which remarkably reduce the cell temperature. For a fixed concentration ratio, the cell temperature reduced as the heat sink area increased. In order to keep the cell at a constant temperature, the heat sink area needs to increase linearly as a function of the concentration ratio. GaInP/GaAs/Ge triple-junction solar cells were fabricated to verify the model. A cell temperature of 37_C was measured when using a heat sink at 400X concentration.
%K heat sink
%K cooling
%K concentrator solar cells
%K thermal dissipation
热沉
%K 散热
%K 聚光太阳电池
%K 热分析
%U http://www.alljournals.cn/get_abstract_url.aspx?pcid=5B3AB970F71A803DEACDC0559115BFCF0A068CD97DD29835&cid=1319827C0C74AAE8D654BEA21B7F54D3&jid=025C8057C4D37C4BA0041DC7DE7C758F&aid=DAA7C8CC1D247757C77976DC029FC131&yid=DE12191FBD62783C&vid=340AC2BF8E7AB4FD&iid=E158A972A605785F&sid=B255C685BA33A869&eid=E158A972A605785F&journal_id=1674-4926&journal_name=半导体学报&referenced_num=1&reference_num=0