%0 Journal Article %T INFLU¨ºNCIA DE DIFERENTES TIPOS DE ELETRODOS SOBRE OS VALORES DA BIOIMPED NCIA CORPORAL E NA ESTIMATIVA DE MASSA MAGRA (MM) EM GATOS ADULTOS INFLUENCE OF DIFFERENT TYPES OF ELECTRODES ON THE BIOELECTRICAL IMPEDANCE VALUES AND IN THE ESTIMATION OF LEAN BODY MASS (LBM) IN ADULT CATS %A Thassila Caccia Feragi Cintra %A J¨²lio Carlos Canola %A Naida Cristina Borges %A Aulus Cavalieri Carciofi %J Ci¨ºncia Animal Brasileira %D 2010 %I Universidade Federal de Goi¨¢s %X A bioimpedancia (BIC) ¨¦ um m¨¦todo que aplica ¨¤ tecnologia da impedancia no estudo da composi o corporal pela avalia o da diferen a da condutividade el¨¦trica dos tecidos. Os resultados da BIC s o expressos pelas medidas prim¨¢rias de resist¨ºncia (R) e reatancia (Xc). Neste experimento, o m¨¦todo foi desenvolvido para verificar a viabilidade do uso de tr¨ºs diferentes tipos de eletrodos sobre a reprodutibilidade dos valores de R e Xc em gatos adultos. As m¨¦dias de R e Xc com adesivos e agulhas de acupuntura n o diferiram entre si (p?0,05), e os menores valores dos coeficientes de varia o obtidos com estes eletrodos sinalizaram para uma melhor reprodutibilidade dos resultados quando comparados com os da agulha hipod¨¦rmica. Os diferentes tipos de eletrodos n o interferiram nos valores da massa magra (MM) estimada por equa o espec¨ªfica, por¨¦m a agulha de acupuntura mostrou ser o eletrodo mais est¨¢vel e de melhor aplicabilidade. A MM determinada com os diferentes tipos de eletrodos foi superior (p?0,05) ¨¤ obtida com a absorciometria de raios-x de dupla energia (DEXA), provavelmente decorrente da equa o utilizada na sua estimativa. PALAVRAS-CHAVES: Composi o corporal, felinos, impedancia, massa magra. The bioelectrical impedance is a method that applies impedance technology in the study of physical composition by evaluation of electrical conductivity difference on each organism tissue. The results of bioelectrical impedance (BIC) are expressed by the resistance (R) and reactance (Xc) primary measures. This study was carried out to verify the viability of the use of three different electrodes on the repeatability of R and Xc values in adult cats. The averages of R and Xc estimated by adhesive and acupuncture needles did not differ from each other (p?0.05) and the smaller values of the variation coefficient acquired with these electrodes signaled for a better reproducibility of the results when compared with hypodermic needle. The different types of electrode did not interfere on the LBM estimated by specific equation, but the acupuncture needle electrode was the most stable and easily applicable. The LBM values determined with the different types of electrode were higher (p?0.05) than the LBM dual-energy X-ray absorptiometry (DEXA) values, probably due to the specific equation to LBM estimation used in this study. KEY WORDS: Body composition, feline, impedance, lean body mass. %K impedancia %K felinos %K massa magra %K composi o corporal %U http://www.revistas.ufg.br/index.php/vet/article/view/4393