%0 Journal Article
%T 格列齐特中对甲苯磺酰胺含量的测定
Determination of p-Toluenesulfonamide Content in Gliclazide
%A 魏乐坤
%J Advances in Analytical Chemistry
%P 25-28
%@ 2163-1565
%D 2012
%I Hans Publishing
%R 10.12677/AAC.2012.23005
%X 目的:建立格列齐特中对甲苯磺酰胺含量的测定方法。方法:采用高效液相色谱法,色谱柱为Agilent ZORBAX Eclipse XDB C8柱,用外标法定量。结果:待测杂质对甲苯磺酰胺在0.4~1.2 μg/ml范围内线性关系良好(r = 0.9993),平均回收率(n = 9)为99.1%。结论:此方法简单、准确、灵敏度高,可用于格列齐特中对甲苯磺酰胺的杂质检查。
Objective: To establish a method for the determination of p-Toluenesulfonamide content in Gliclazide. Methods: Using High Performance Liquid Chromatography (HPLC) method with an Agilent ZORBAX Eclipse XDB C8 column. External standard method for quantitative. Results: The liner range of impurity p-Toluenesulfonamide was 0.4 - 1.2 g/ml, which showed good linearity (r = 0.9993). The average recovery was 99.1%. Conclusions: The method is simple, accurate and sensitive. It can be used for the determination of p-Toluenesulfonamide limit in Gliclazide.
%K 高效液相色谱法;格列齐特;对甲苯磺酰胺
High Performance Liquid Chromatography (HPLC)
%K Gliclazide
%K p-Toluenesulfonamide
%U http://www.hanspub.org/journal/PaperInformation.aspx?PaperID=914