%0 Journal Article %T Contaminaci車n del aire interior en un proyecto de viviendas con climatizaci車n centralizada Indoor air pollution in a housing project fitted with central air-conditioning %A Enrique Molina Esquivel %A Dayam赤 Cuba Vald谷s %J Revista Cubana de Higiene y Epidemiolog赤a %D 2006 %I ECIMED %X La contaminaci車n del aire interior de las viviendas ejerce una importante influencia sobre la salud de la poblaci車n y grupos de riesgo, a pesar de lo cual resultan escasos los estudios realizados en Cuba. Se efectu車 un estudio descriptivo en un apartamento de un prototipo de edificio t赤pico de viviendas con climatizaci車n centralizada. Durante cinco d赤as consecutivos se determinaron las concentraciones sincr車nicas horarias de di車xido de nitr車geno (NO2 ) en la cocina y la sala de la vivienda y en el exterior de esta, con la cocina de gas apagada y posteriormente encendida, as赤 como las medias diarias de di車xido de azufre (SO2 ) y part赤culas en suspensi車n totales (PST) en la sala y en el exterior. La climatizaci車n se mantuvo en la m赤nima capacidad de enfriamiento y las ventanas cerradas. Las concentraciones medias diarias de SO2 en el interior de la vivienda resultaron superiores a las registradas de forma sincr車nica en el exterior, en tanto que para las PST ocurri車 lo inverso. En ambos casos los valores observados fueron inferiores a las concentraciones m芍ximas admisibles. Con el encendido de la cocina de gas se produjo un incremento de las concentraciones horarias de NO2 en el interior de la vivienda, las que superaron la concentraci車n m芍xima admisible. La acumulaci車n de NO2 demostr車 la insuficiente tasa de renovaci車n del aire interior contaminado por parte del sistema de climatizaci車n, el escaso aprovechamiento de la ventilaci車n natural y la dudosa sostenibilidad ambiental del dise o. Se formularon recomendaciones. Indoor air pollution in dwellings heavily influences the population∩s and the risk groups∩ health. Despite this, few studies have been conducted on this topic in Cuba. A descriptive study was carried out in an apartment located in a typical building prototype fitted with central air-conditoning. For five days, synchronic hourly nitrogen dioxide (NO2) concentrations were measured in the kitchen and the living room as well as outdoors, with the gas stove out and later ignited whereas daily sulphur dioxide means (SO2) and total suspended particles were determined the living room and outdoors. Air-conditioning was kept at the minimun cooling rating and the windows remained closed. Daily mean concentrations of S02 inside the house exceeded those recorded outdoor whereas it was the opposite in TSP. The estimated values in both cases were lower than the allowable maximum concentrations. The ignition of the gas stove brought about higher hourly N02 concentrations inside the house, which were over the allowable maximum concentrations. Accumulated N02 %K Contaminaci車n del aire interior de viviendas %K di車xido de nitr車geno %K part赤culas en suspensi車n %K di車xido de azufre %K Indoor air pollution in dwellings %K nitrogen dioxide %K suspended particles %K sulfur dioxide %U http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S1561-30032006000300004