%0 Journal Article %T Biomechanical evaluation of three surgical scenarios of posterior lumbar interbody fusion by finite element analysis %A Zhitao Ziao %A Liya Wang %A He Gong %A Dong Zhu %J BioMedical Engineering OnLine %D 2012 %I BioMed Central %R 10.1186/1475-925x-11-31 %X Finite element analysis (FEA), as an efficient tool for the analysis of lumbar diseases, was used to establish a three-dimensional nonlinear L1-S1 FE model (intact model) with the ligaments of solid elements. Then it was modified to simulate the three scenarios of PLIF. 10£¿Nm moments with 400£¿N preload were applied to the upper L1 vertebral body under the loading conditions of extension, flexion, lateral bending and torsion, respectively.Different mechanical parameters were calculated to evaluate the differences among the three surgical models. The lowest stresses on the bone grafts and the greatest stresses on endplate were found in the PCT model. The PCP model obtained considerable stresses on the bone grafts and less stresses on ligaments. But the changes of stresses on the adjacent discs and endplate were minimal in the PAIB model.The PCT model was inferior to the other two models. Both the PCP and PAIB models had their own relative merits. The findings provide theoretical basis for the choice of a suitable surgical scenario for different patients. %K Spine %K Cage %K PEEK %K Autogenous iliac bone %K Ligaments %U http://www.biomedical-engineering-online.com/content/11/1/31/abstract