Harmonic Investigation of Compact Fluorescent Lamps Low Energy Consumption Lamps of Cameroonian Market

DOI: 10.4236/oalib.1105446, PP. 1-11

Subject Areas: Electric Engineering

Keywords: Harmonic, Pollution, Compact Fluorescent Lamp, THD, Spectrum Harmonic

Full-Text   Cite this paper   Add to My Lib

Abstract

This article presents a study of compact fluorescent lamps (CFLs) low energy consumption lamps found in the Cameroonian market. The current obtained in the experimental setup has been analyzed in Matlab Simulink. The results obtained show that the THD of different lamps does not respect the standard IEC-61000-3-2. These values increase with the power of lamps. Spectral analysis of these lamps shows that the probable cause of their premature degradation results from the effects of harmonics on the capacitors. This degradation is all more precocious as the rank and the concerned THDi is great. That’s why 75 W lamps are more sensitive than others.

Cite this paper

Ngoffe, S. P. , Essiane, S. N. , Offole, F. , Mengounou, G. M. , Imano, A. M. and Onambele, O. (2019). Harmonic Investigation of Compact Fluorescent Lamps Low Energy Consumption Lamps of Cameroonian Market. Open Access Library Journal, 6, e5446. doi: http://dx.doi.org/10.4236/oalib.1105446.

References

[1]  Schneider Electric (2015) Elimination des harmoniques dans les installations. Edition 09/2015, 1-21.
[2]  Nohra, M.A.H. (2017) Commande de Filtres Actifs Parallèles sur un Réseau Fortement Perturbé. Ph.D. Thesis, Toulouse University, Tou-louse.
[3]  Hanna Nohra, A.F., Kanaan, H.Y. and Al-Haddad, K. (2012) A Study on the Impact of a Massive Integration of Compact Fluorescent Lamps on Power Quality in Distribution Power Systems. International Conference on Renewable Ener-gies for Developing Countries (REDEC), Beirut, 28-29 November 2012, 1-6.
https://doi.org/10.1109/redec.2012.6416700
[4]  Collombet, C., Lupin, J.M. and Schonek, J. (1999) Perturbation harmoniques dans les réseaux polluésetleur traitement. Schneider Electric, cahier technique no. 152.
[5]  Abbaspour, M. and Jahanikia, A.H. (2009) Power Quality Consideration in the Widespread Use of Compact Fluorescent Lamps. 10th International Conference on Electrical Power Quality and Utilisation, Lodz, 15-17 September 2009, 1-6.
https://doi.org/10.1109/epqu.2009.5318824
[6]  Richard, M.K. and Sen, P.K. (2010) Compact Fluorescent Lamps and Their Effect on Power Quality and Application Guidelines. IEEE Industry Applications Society Annual Meeting, Houston, 3-7 October 2010, 1-7.
https://doi.org/10.1109/ias.2010.5615449
[7]  CEI 61000-3-2 Compatibilité électromagnétique (CEM) (2009)—Partie 3-2: Limites—Limites pour lesémissions de courant harmonique (Courant appelé par les appareils 16A par phase) édition 3.2-2009.
[8]  CEI 61000-2-2 Compatibilité Electromagnétique (CEM)—Partie 2-2 (2002): Environnement-Niveaux decompatibilité pour les perturbations conduites à basse fréquence et la transmission des signaux surles réseaux publics d'alimentation basse tension. Deuxième édition 2002-03.
[9]  IEC 61000-2-4 Compatibilité électromagnétique (CEM)—Partie 2-4 (2002): Environnement—Niveauxde compatibilité dans les installations industrielles pour les perturbations conduites à bassefréquence. Deuxièmeédition 2002-06.
[10]  Hanna Nohra, A.F., Kanaan, H.Y. and Fadel, M. (2016) Comparative Evaluation of Harmonic Compensation Methods Based on Power Calculation and Current Harmonic Detection for Single-Phase Applications. IECON 2016—42nd Annual Conference of the IEEE Industrial Electronics Society, Florence, 23-26 October 2016, 3685-3690. https://doi.org/10.1109/iecon.2016.7793331
[11]  Schonek, J. (2000) Les singularités de l’harmonique 3. Schneider Electric, cahier technique n 202.
[12]  Czarnecki, L.S. (1987) What Is Wrong with the Budeanu Concept of Reactive and distortion power and Why It Should Be Abandoned. IEEE Transactions on Instrumentation and Measurement, IM-36, 834-837.