oalib

Publish in OALib Journal

ISSN: 2333-9721

APC: Only $99

Submit

Any time

2019 ( 70 )

2018 ( 5457 )

2017 ( 5254 )

2016 ( 5259 )

Custom range...

Search Results: 1 - 10 of 294167 matches for " br>戴景民 "
All listed articles are free for downloading (OA Articles)
Page 1 /294167
Display every page Item
MULTI-WAVELENGTH PYROMETER AND ITS APPLICATIONS
多波长辐射测温仪及其应用

Dai Jingmin,Yang Maohu,Chu Zaixiang,<br>,杨茂华
红外与毫米波学报 , 1995,
Abstract: The latest achievements and status in Multi-Wavelength Pyrometer (MWP)have been reviewed. Its applications are introduced,too.
TRUE TEMPERATURE MEASUREMENT BY RADIATION METHOD BASED ON NEURAL NETWORK MODEL
基于神经网络模型的辐射真温测量方法研究

SUN Xiao,Gang,DAI Jing,Min,CONG Da,Cheng,CHU Zai,Xiang,<br>孙晓刚,
红外与毫米波学报 , 2001,
Abstract: The theory of neural networks was applied in the field of multi spectral radiation thermometry. The experimental results show that the above mentioned method is an effective method for solving the true temperature measurement.
STUDY OF THE APPLICATION OF RBF NETWORK TO MULTI-SPECTRAL THERMOMETRY
RBF网络在多光谱测温中的应用研究

CONG Da,Cheng,DAI Jing,Min,SUN Xiao,Gang,CHU Zai,Xiang,<br>丛大成,
红外与毫米波学报 , 2001,
Abstract: The application of artificial neutral network to data processing of multi spectral radiation thermometry was presented. By taking advantages of neutral network and various emissivity samples, the emissivity models of the targets were identified and the true temperature and spectral emissivity were available simultaneously. The measurement accuracy was improved further by subdivision. The effects of measurement errors on the measurement accuracy of temperature and emissivity were also analyzed. Computer simulation results proved that the method is an effective way for both temperature and emissivity measurements.
MONTE-CARLO SOLUTIONS FOR INFRARED STANDARD RADIATION SOURCES
红外标准辐射源特性的蒙特—卡罗解

DAI JINGMIN,HE JIN,CHEN WENXIAN,CHU ZAIXIANG,<br>,何谨,陈文贤,褚载祥
红外与毫米波学报 , 1993,
Abstract: Some methods for evaluating the radiation characteristics of infrared standard radiation sources with specularly reflecting surfaces are presented in this paper. The Monte-Carlo method is stressed and the calculated results and relevant important conclusions for these blackbody cavities by using this method are also summarized.
DEVELOPMENT OF SPECTRAL EMISSIVITY MEASUREMENT SYSTEM BASED ON FOURIER TRANSFORM INFRARED SPECTROMETER ( FTIR )
基于傅里叶红外光谱仪的光谱发射率测量装置的研制

WANG Xin-Bei,XIAO Peng,DAI Jing-Min,<br>王新北,萧鹏,
红外与毫米波学报 , 2007,
Abstract: 基于傅里叶红外光谱仪成功研制了固体材料光谱发射率测量装置,它由一个试样加热炉、一个参考黑体炉、水浴环境腔体及真空系统等组成,可以实现100-1500℃及光谱0.66-25μm范围内固体材料光谱发射率测量.参考黑体用于对系统的标定,水浴环境腔体和真空系统用来消除环境和大气的影响.装置调试后对某种航天用材料做了测试实验,得到了很有规律的结果.估计了系统的不确定度:发射率不确定度小于2.27%(3δ,ε=0.9),6.80%(3δ,ε=0.3).
红外标准辐射源特性的蒙性—卡罗解
,何谨
红外与毫米波学报 , 1993,
Abstract:
DEVELOPMENT OF MULTI-POINT MULTI-WAVELENGTH PYROMETER WITH A SYNCHRONOUS DAS
具有同步数据采集系统的多点多波长高温计的研制

DAI Jing-Min,LU Xiao-Dong,CHU Zai-Xiang,KANG Song-Gao,FAN Chuan-Xin,<br>,卢小冬
红外与毫米波学报 , 2000,
Abstract: A new type of multi-point multi-wavelength pyrometer for solid propellant rocket engine flame distribution measurement was developed successfully. The instrument can record the radiation fluxes of 8 wavelengths for uniformly distributed 6 points on the target surface, which are well defined by the holes on the field stop lens. The fast-response pyrometer with the specially designed synchronous data acquisition system can assure that the recorded thermal radiation fluxes of different spectrum region are of the same time and the same true temperature even with dramatically changed targets.
THEORETICAL STUDY OF MULTI-WAVELENGTH RADIATION THERMOMETRY--Autosearch for Emissivity Expression General
多光谱辐射测温的理论研究

SUN Xiao-gang,DAI Jing-Min,CONG Da-cheng,CHU Zai-Xiang,<br>孙晓刚,
红外与毫米波学报 , 1998,
Abstract: 在多光谱辐射温度计的数据处理中的常假设发射率的对数与波长成线性关系,本文提出卫种自动判别发射率和波长数学模型的新方法,着重分析了应用此方法时各种测量误差对真温及发射率的影响,计算机仿真结果与理想假设值符合得很好,是一种较好的获知真温及发射率的方法。
Dim moving target detection in multispectral IR image sequence based on GLRT
基于GLRT的红外多光谱弱小运动目标检测

WANG Jian-Lai,YANG Chun-Ling,DAI Jing-Min,<br>王暕来,杨春玲,
红外与毫米波学报 , 2011,
Abstract: The scope of this paper addresses the problem of detecting a dim moving target from a sequence of multispectral IR cubes. In this work, the detection problem is formulated in a general framework, assuming unknown target amplitude, position and velocity. This composite hypothesis testing problem is approached by means of the generalized likelihood ratio test (GLRT) theory. The detector structure and its actual implementation based on velocity filters are discussed in detail. Approximated expressions of the false alarm and detection probabilities are obtained and validated by means of simulation. To test the effectiveness of the detection algorithm, the detection results obtained on a set of synthetic multispectral IR image sequences are presented and discussed, and these results indicate that the algorithm proposed in this paper can obtain a good performance on dim target detection with low SNR.
DESIGN OF MID-INFRARED MULTI-WAVE-LENGTH RADIATION THERMOMETER
中红外多波长辐射温度计的设计

CONG Da-Cheng,DAI Jing-Min,SUN Xiao-Gang,CHU Zai-Xiang,<br>丛大成,,孙晓刚,褚载祥
红外与毫米波学报 , 2000,
Abstract: A brand-new kind of mid-infrared multi-waveleng th radiation thermometer for the measurement of true temperature and emissivity near room temperature with high signal-to-noise ratio (SNR) was presented. By ap plying blazed grating and refractive-reflected optical system with high image q u ality and throughput, the temperature and emissivity were available simultaneous ly by the MCT semiconductor sensor array and electric system. Inner blackbody so urce was installed to compensate the surrounding temperature drift, and the temp erature of field stop and aperture stop was controlled by a heat pipe to reduce th e influence of stray radiation on temperature measurement. The main structures o f optical and electric systems were described in detail.
Page 1 /294167
Display every page Item


Home