oalib
Search Results: 1 - 10 of 100 matches for " "
All listed articles are free for downloading (OA Articles)
Page 1 /100
Display every page Item
Predimensionado óptimo de secciones mixtas de hormigón y acero: criterios del Eurocódigo 4  [cached]
Monfort Lleonart, José,Pardo Ros, José Luis,Guardiola Villora, Arianna
Informes de la Construccion , 2001,
Abstract: The analysis of composite steel-concrete beams requires to set, previously. the dimensions of each part of the beam for proceeding after that to adjuste them by un iterative process up to reach a reasonable approximation; the initial definition of that kind of sections is not easy because are involved a great number of parameters. This paper develops a direct procedure for obtaining the above mentioned pre-design of the beam including optimization criteria and a practica1 application by the use of tables containing usual edification situations. El cálculo de vigas mixtas de hormigón y acero se realiza a partir de un predimensionado de la sección que se ajusta por un proceso iterativo hasta alcanzar una aproximación razonable; la definición inicial de la sección es compleja por las numerosas variables que intervienen. En este articulo se plantea un método de predimensionado incluyendo criterios de optimización, de fácil aplicación práctica por medio de tablas que corresponden a situaciones usuales en edificación.
El comportamiento post-critico de las vigas de acero armadas con chapas delgadas  [cached]
Torregiani, C. L.,Cervera, H. A.,Cecchini, A. E. F.,Moncada, N. E.
Informes de la Construccion , 1986,
Abstract: An advance of expositions concerning the method of ultimate strength or post-critical strength of steel beams reinforced with thin plates is presented. This method is being object of experimental researches at the Applied Mechanics and Structures Institute (IMAE) of the Mathematics and Engineering Faculty, National University, Rosario (Argentina). Se presenta un avance de planteamientos relativos al método de la resistencia última o resistencia post-crítica de vigas de acero armadas con chapas delgadas, el cual está siendo objeto de investigaciones experimentales en el Instituto de Mecánica Aplicada y Estructuras (IMAE) de la Facultad de Ciencias Exactas e Ingeniería de la Universidad Nacional de Rosario (República Argentina).
Predimensionado óptimo de secciones mixtas de hormigón y acero en régimen elástico  [cached]
Monfort Lleonart, José
Informes de la Construccion , 1985,
Abstract: Applying the method of the ideal section to calculate the concrete and Steel composite sections in elastic regime, two purposes appear: 1) To establish an adequacy criterion to avoid the paradoxal case in which the standard rolled steel section alone reaches more resistance, in elastic phase, than reinforcing it with a concrete slab forming a composite beam. 2) To define a criterion to obtain the best pre-design, intending to reach, at the same time, the admissible stresses in the most compressed concrete fibre and in the most tensioned steel. Finally, the results corresponding to some frequent steel sections and concrete qualities usual in building, have been settled in tables of easy practical application, for the pre-design of sections starting from the tensional state. Aplicando el método de la sección ideal para el cálculo de secciones mixtas de hormigón y acero en régimen elástico, se plantean dos objetivos: 1) establecer un criterio de adecuación, para evitar el caso paradójico en que sólo el perfil metálico alcanza más resistencia, en fase elástica, que al reforzarlo con una cabeza de hormigón formando la viga mixta; 2) definir un criterio de optimización para el predimensionado, en base a que se alcancen simultáneamente las tensiones admisibles en la fibra más comprimida del hormigón y en la más traccionada del acero. Finalmente se han recogido en tablas, de fácil aplicación práctica para el predimensionado de secciones a partir del estado tensional, los resultados correspondientes a algunos perfiles comerciales y calidades de hormigón usuales en edificación.
Capacidad Resistente a Flexión y Cortante de Vigas de Acero Mediante la Aplicación Mathcad Flexure Resistance and Shear Capacity of Steel Beams using Mathcad  [cached]
R. Cede?o-Rosete,J.C. Gatica-Galina
Información Tecnológica , 2005,
Abstract: Se presenta la implementación de un programa de cómputo para determinar la capacidad resistente a flexión y cortante de perfiles de acero. La metodología se basa en el criterio de dise o Factores de Carga y Resistencia establecida en el reglamento del Instituto Americano de Construcción en Acero (AISC). Se generan hojas de cálculo en la aplicación Mathcad de fácil utilización. Se plantean dos ejemplos de vigas de acero obteniendo su capacidad resistente a flexión y cortante para cargas uniformes y concentradas y se comparan los resultados con las acciones últimas especificadas. El programa también cumple las funciones de dise o estructural permitiendo al usuario obtener el perfil más económico para la solución de un problema. La aplicación resulta ser un material de interés práctico profesional y de utilidad didáctica para cursos de dise o en acero. A computer program was developed to determine the flexure and shear resistance capacity of steel beams. The methodology was based on the Load Resistance Factor Design (LRFD) criteria of the American Institute of Steel Construction code (AISC). Easy to use working spreadsheets were developed using Mathcad. Two examples are solved for steel beams subjected to uniform and concentrated loads, comparing their flexural and shear resistance capacities under these loads. The program also fulfills structural design features allowing the user to obtain the most economic steel shape to solve a problem. The resultant application is of practical professional interest and also serves as additional teaching material in courses of steel design.
Comportamiento de vigas de sección compuesta con perfiles de acero laminado y losa de concreto empleando conectores de cortante tipo tornillo grado dos (2) Laminated steel and concrete slab composite beam behavior using grade two shear connector screws  [cached]
García Zamora Alejandro,Molina Herrera Maritzabel
Ingeniería e Investigación , 2008,
Abstract: En el presente artículo, partiendo de un análisis teórico-experimental, se determinan y caracterizan los parámetros de dise o que rigen el comportamiento de las vigas compuestas de perfiles de acero y losa de concreto empleando conectores de cortante tipo tornillo, dado que para esta clase de conector no existe un estudio específico de su comportamiento, además en la actualidad su dise o no está definido en las NSR-98, aunque es uno de los tipos de conectores más empleados en la construcción de sec-ciones compuestas en Colombia. El análisis se desarrolló con base en los resultados de 36 ensayos experimentales a escala, para dos resistencias de concreto (f’c), 21MPa y 28MPa, cada resistencia de concreto con tres diámetros de tornillos, 1/2”, 5/8” y 3/4”, con dos tipos de separaciones de 0,10 m y de 0,30 m. En esta investigación se estudian, entre otros efectos, el deslizamiento producido tanto por la degradación del concreto como por las deformaciones en el perfil de acero y en los co-nectores, para ello se emplean formulaciones que involucran diversas variables como el deslizamiento y la separación de los co-nectores. Así mismo, en el estudio se plantea una metodología de dise o de vigas en sección compuesta con conectores de cor-tante tipo tornillo, donde se propone una formulación para el cálculo de la resistencia de los conectores de cortante, con la cual se obtienen resistencias de los conectores del orden del 62% de las planteadas para los espigos cuando la separación es de 0,10 m y 13% mayores para las separaciones de 0,30 m, en los parámetros elásticos donde se obtienen inercias efectivas del orden de 62% de las teóricas y en de resistencia a flexión de las vigas compuestas, las cuales mostraron una sobrerresistencia promedio del 23% mayor de los valores nominales de la normatividad actual. This paper reports using theoretical-experimental analysis for obtaining and characterising the design parameters governing steel and concrete slab composite beams’ behaviour using shear connector screws. Currently no research has been found about such behaviour and Colombian seismic-resistant regulations (NSR-98) have not yet defined such design; these types of connectors are most used in constructing composite sections in Colombia. The results of 36 experimental scale tests for 21MPa and 28MPa con-crete strengths were taken for the analysis; each concrete strength had three screw diameters ( 1/2 ", 5/8 " and 3/4 ") with 0.10m and 0.30m separations. This research also studied other effects such as slip caused by steel and connector profile defor-mation o
Resistencia de vigas armadas de acero sometidas a cargas concentradas en secciones no rigidizadas Resistance of unstiffened steel plate girders subjected to concentrated loads
Rolando Chacón,Enrique Mirambell,Esther Real
Boletín Técnico , 2009,
Abstract: Las cargas concentradas en vigas armadas deben ser soportadas por rigidizadores verticales dispuestos en las secciones transversales solicitadas. Sin embargo, existen casos prácticos en los cuales resulta físicamente imposible la rigidización de todas las secciones de la viga que se verán sometidas a dichas solicitaciones. Un ejemplo paradigmático de estos casos es la construcción de puentes metálicos por empujes sucesivos. El presente artículo describe las expresiones de dise o actualmente implementadas en diferentes normativas a nivel mundial para la verificación de la resistencia de las vigas bajo cargas concentradas en secciones no rigidizadas. Asimismo, se presentan los modelos mecánicos en los cuales se basan las diferentes normativas así como las referencias más destacadas sobre el tema. Concentrated loads on steel plate girders should be carried by vertical transverse stiffeners deployed on each loaded cross-section of the members. There are, however, certain design cases in which vertical stiffeners cannot be physically deployed in such sections. The launching of steel bridges during construction is one remarkable realistic case in which this situation arises. Accordingly, the resistance of steel girders to such loads must be known and understood. This paper describes the design provisions presently implemented in codes for verifying the resistance of plate girders subjected to concentrated loads. Likewise, references and theoretical backgrounds of the aforementioned guidelines are pointed out.
Aumento de la capacidad flectora de vigas de edificación  [cached]
Ramírez Ortiz, José Luís,Bárcena Díaz, José Manuel
Informes de la Construccion , 1980,
Abstract: Two methods for reinforcing beams are described from the point of view of the bending moment, continuing with a research program on the reinforcement of pillars and beams executed in reinforced concrete, the results of which have been progressively published in this periodical. The two procedures consist of: one - chipping of the concrete of the top part, insertion of reinforcement frames and fresh concreting with the adhering of a steel plate in the bottom of the beam; two - exclusively the adhering of two plates, one in the top part and the other in the lower part of the beam. The results of the tests confirm the interest for building of the method and the validity of its method of calculation and, in the following part, the information relative to the theory of the reinforcements put forth, their execution and behavior for usage and breaking loads is given. Se describen dos métodos de refuerzo de vigas desde el punto de vista del momento flector, continuando con un programa de investigación de refuerzo de pilares y vigas de hormigón armado en edificación, cuyos resultados se han ido publicando en esta revista. Los dos procedimientos consisten: uno en picado del hormigón de la parte superior, inserción de armaduras de refuerzo y nuevo hormigonado junto con el pegado de una chapa de acero en el fondo de la viga; y otro en exclusivamente el pegado de dos chapas, una en la parte superior y otra en la inferior de la viga. Los resultados de los ensayos confirman el interés del método y la validez de su método de cálculo y, en lo que sigue, se da la información relativa al planteamiento teórico de los refuerzos, a su realización y a su comportamiento para carga de servicio y rotura.
Refuerzo de elementos estructurales mediante bandas de acero adheridas con resinas epóxicas
Cifuentes Cifuentes Gustavo
Ingeniería e Investigación , 1995,
Abstract: This paper presents the results of test carried out on reinforced concrete beams strengthened by epoxy-bonded steel plates in the Universidad Nacional de Colombia. The test shown the very good behavior of reinforced beams whit additional bonded plates when they have additional anchor plates that can overcome the problem of anchorage failure. When the reinforced beam does not have additional anchor plates, the beam present greater values of stiffness, but they have a non-ductile behavior. EI presente artículo muestra los resultados experimentales y las conclusiones de una investigación llevada a cabo en la Universidad Nacional de Colombia, acerca del comportamiento de vigas de concreto reforzado, con refuerzo adicional consistente en laminas de acero adheridas, mediante resinas epóxicas. Los resultados experimentales, demuestran el buen comportamiento que tiene este tipo de refuerzo siempre y cuando se disponga de un sistema adicional de anclaje de las láminas de acero. Aunque no se disponga de anclaje adicional se comprobó un aumento de rigidez en las vigas estudiadas.
Análisis del rendimiento estructural de vigas Vierendeel  [cached]
Estévez Cimadevila, Javier,Martín Gutiérrez, Emilio
Informes de la Construccion , 2003,
Abstract: This article approaches the analysis of the structural efficiency of the Vierendel beams. This assessment involves two variables: one relates to the strength-efficiency and the other one to the global efficiency. (The global efficiency fakes also into account the bending stiffness f the beam). The results shown reflect the analysis and dimensioning of over 400 beams, where a series of five different modulations combined with seven different beam depths have been used. The case study finishes using two types of profiles (hollow and open section) and comparing the structural behaviour between beams and trusses. The graphs shown are a very useful tool in order to assess the effect of these beams' design parameters on their structural efficiency. The most important result of the case study is the fact that using high beam depths in un optimized dimensioning involves a decrease of the efficiency This criteria differs from the criteria for latticed structures. El presente artículo aborda el análisis del rendimiento estructural de vigas Vierendeel. Dicha valoración se determina a través de dos índices, uno relativo al rendimiento resistente y otro al rendimiento global, que tiene en cuenta además la rigidez del conjunto a flexión. Los resultados mostrados responden al análisis y dimensionado de más de 400 vigas, en las que se han utilizado una serie de cinco modulaciones en combinación con siete valores de canto diferentes. El estudio se completa con el empleo de dos tipos de perfiles (tubular y abierto) y con la comparación de su comportamiento con el de las vigas trianguladas. Las gráficas aportadas constituyen una herramienta de gran utilidad en orden a valorar la incidencia de los parámetros de dise o de estas vigas en su rendimiento estructural, poniendo de manifiesto como conclusión más relevante la pérdida de eficiencia que se produce, en un dimensionado optimizado, con la utilización de cantos elevados, contrariamente a los criterios vigentes en las soluciones de celosía.
ENSAYOS A CORTANTE DE VIGAS DE HORMIGóN ESTRUCTURAL AUTOCOMPACTABLE  [cached]
CLAUDIA JENNY DE LA CRUZ,JOSé TURMO,RAVINDRA GETTU,BRYAN BARRAGáN
DYNA , 2009,
Abstract: En el presente trabajo se presenta una serie de ensayos realizados en el Laboratorio de Tecnología de Estructuras de la Escuela de Ingenieros de Caminos, Canales y Puertos de Barcelona (Departamento de Ingeniería de la Construcción) de la Universidad Politécnica de Catalu a. La campa a de ensayos incluía una serie de vigas de sección "doble T" de hormigón autocompactable de resistencia media (HAC-RM) y una serie paralela realizada con hormigón convencional (HC) de la misma resistencia mecánica. Se verificó el comportamiento estructural frente al esfuerzo cortante de vigas de hormigón armado y pretensado con armadura pretesa y postesa, y tanto estructuras continuas como isostáticas. Los resultados muestran una menor resistencia a cortante en las vigas con HAC y armadura pasiva y activa. Para las vigas pretensadas con HAC y HC los valores de resistencia a cortante fueron similares.
Page 1 /100
Display every page Item


Home
Copyright © 2008-2017 Open Access Library. All rights reserved.