oalib
Search Results: 1 - 10 of 100 matches for " "
All listed articles are free for downloading (OA Articles)
Page 1 /100
Display every page Item
abbuvisor火检系统在华润登封电厂的应用  [PDF]
李献忠,王国坤,薛照伟
热力发电 , 2009,
Abstract: 介绍了abbuvisor系列火焰检测系统在华润电力登封有限公司(华润登封电厂)一期2×300mw机组锅炉上的应用情况。针对锅炉运行中出现的燃烧器结焦影响火检探头视线、煤质差挥发分降低和一次风温度低导致燃烧黑区延长的问题,对该火焰检测系统进行了优化调试。结果表明,如果能够利用mfd的4套参数自动优化功能,引入不同负荷自动调用不同参数功能,该火检系统会更好地满足运行要求。
火电机组回热系统火用损分布的矩阵算法  [PDF]
李永华,苗鑫华,李庚生,闫顺林
热力发电 , 2007,
Abstract: 根据火电机组回热系统火用损分布的通用矩阵方程,运用mathcad软件计算了200mw和600mw机组两套典型回热系统的火用损,并与传统火用损计算方法的计算结果进行比较,详细介绍了该方程的应用方法和使用技巧。通过火用分析,找出了这两套回热系统的节能潜力所在,并用棒状图对4种火用分析指标进行比较,证明了火用损率和火用损系数更能表现回热系统的完善程度。
室内热环境参数对人体火用损的影响研究  [PDF]
吴小舟,,赵加宁,王沣浩
- , 2015,
Abstract: 从热力学角度探讨了室内热环境对人体火用损的影响,提出了人体火用及人体火用损的定义,并确定了人体火用计算的基准点.然后以冬季典型办公房间为研究对象,定量分析了室内热环境参数对人体火用损的影响,发现当空气相对湿度为10%~50%时,室内空气温度和室内平均辐射温度的变化对人体火用损影响较大,而当室内空气温度和室内平均辐射温度均小于20 ℃时,室内空气相对湿度的变化对人体火用损影响较小.
The effect of indoor thermal environmental parameters on human body exergy consumption was analyzed from the thermodynamic point of view. The definitions of human body exergy and human body exergy consumption were given, and also the calculation base point of human body exergy. Typical office building environment in winter was selected as research object, and the effect of indoor thermal environmental parameters on human body exergy consumption was quantitatively analyzed. The results show that the change of indoor air temperature or mean radiant temperature has relatively small effect on the human body exergy consumption when indoor air relative humidity ranges from 10% to 50%, and the change of indoor air relative humidity has relatively large effect on the human body exergy consumption when both indoor air temperature and mean radiant temperature are less than 20 ℃.
基于矩阵法的660mw机组回热系统火用损分析  [PDF]
薛青鸿,吕智嘉,李亚峰
热力发电 , 2011,
Abstract: 根据某660mw机组回热系统结构及参数,给出了火用损分布矩阵方程。选取100%、75%、50%、30%负荷工况点,对回热加热器火用损和火用效率进行了定量计算与分析。结果表明,当传热量及加热器结构一定时,为了降低换热温差,则必须设法增大换热系数,如减小阀门阻力、提高工质流速等。
冰蓄冷低温送风空调系统(火用)损因素分析
Analysis on exergy loss factors of a novel ice storage system with cold air distribution
 [PDF]

周学丽,李念平,邹杰
- , 2016, DOI: 10.11835/j.issn.1674-4764.2016.02.018
Abstract: 低温送风空调系统引进新型冰蓄冷设备,采用正丁烷作为制冷剂,制冷剂与水直接接触,换热更强烈且稳定。为了研究该系统相应(火用)损因素条件下的节能薄弱环节,实现系统性能优化,基于该系统及各表冷器(火用)分析模型,分析了热湿比、新风比、送风温差等(火用)损因素对系统(火用)效率和各表冷器(火用)损率的影响。结果表明:当热湿比变化时,处理二次混风的表冷器(火用)损率随之呈正比变化,其他表冷器(火用)损率及系统(火用)效率随之呈反比变化;当新风比变化时,处理新风的两级表冷器(火用)损率随之呈正比变化,其他表冷器(火用)损率及系统(火用)效率随之呈反比变化;当送风温差变化时,处理一次回风的表冷器(火用)损率随之呈正比变化,其他表冷器(火用)损率及系统(火用)效率随之呈反比变化。
An exergy analysis model was developed for a novel ice storage system with cold air distribution and its main surface air coolers. Based on this model, the influence of heat and humidity ratio, fresh air ratio and temperature difference between supply air and indoor air on the exergy efficiency of the system and the exergy loss rate of its surface air coolers was studied. Finally the important parameters for system optimization were identified. The simulation results show that the exergy loss rate of the surface air cooler for secondary mixed air is positively proportional to the variation of heat and humidity ratio, while it is inverse for the other; the exergy loss rate of the surface air coolers for fresh air is positively proportional to the variation of fresh air ratio, while it is opposite for the other; the exergy loss rate of the surface air cooler for primary mixed air is positively proportional to the variation of temperature difference between supply air and indoor air, while it is inverse for the other.
基于远程通信和学习功能的电厂火检监控系统  [PDF]
陈荣保,朱勇军,费敏锐
电力系统自动化 , 2006,
Abstract: 介绍了一个已经成功运行的基于远程通信和学习功能的火检监控系统。该系统结合通信技术、计算机技术、自动控制技术以及信息处理技术,将原来现场检测环节中较为庞大的信号线路简化到只有2根通信线缆,并增加了自学习和远程编程监控功能,不仅优化了集散控制系统(DCS),提高了数据的准确度和整个系统的可靠度,也使现场检测设备的维护更加容易和简便。
加热器端差对汽轮机组回热系统火用损分布影响的通用计算模型  [PDF]
曾庆华,于淑梅,周雪斌,韩彦广
热力发电 , 2012,
Abstract: 以基于熵分析法的回热系统火用损分布矩阵方程及汽水分布矩阵方程为基础,结合某台300mw汽轮机组回热系统,进行了数学推导与归纳,获得了加热器端差变化对回热系统火用损分布影响的通用计算模型。该模型只需要通过加热器出口水参数及上级加热器疏水参数的偏差值,即可准确快捷地计算出回热系统的火用损分布变化,且具有良好的适应性与通用性,同时也便于在线定量分析端差变化对回热系统火用损分布的影响。
?柴油机多品位余热回收低火用损跨临界联合循环模拟  [PDF]
?舒歌群,许晓菲,田华,贾琦,孙秀秀,刘丽娜
天津大学学报(自然科学与工程技术版) , 2014, DOI: 10.11784/tdxbz201305074
Abstract: ?为了提高柴油机多品位、大温差余热的回收利用率,提出了一种低火用损跨临界有机朗肯联合循环,其中高温级循环用于回收温度较高的柴油机排气余热和废气再循环(egr)余热,低温级循环回收柴油机冷却水余热、增压空气余热、与高温级循环换热后的排气余热和egr余热.高温级对比分析了3种硅氧烷工质mm、mdm和d4,低温级选用了r143a,模拟研究了高低温级参数对循环性能的影响.结果表明:高低温级均存在最优的蒸发压力,高温级冷凝压力在允许范围内越低越好;高温级采用mm较mdm和d4循环性能更好,循环净功最高可以达到36.36,kw,损只有4.5,kw;各部分余热的利用率均在86%以上;增加高低温级的回热效能均可以提高循环性能.
整体煤气化联合循环(IGCC)火用损分布结构研究  [PDF]
刘泽龙,金红光,林汝谋
工程热物理学报 , 2000,
Abstract: 整体煤气化联合循环是一种先进的洁净煤发电技术。本文应用火用分析方法,研究IGCC中七个子系统(空分、气化、净化、压气机、燃烧室、透平、余热锅炉及汽机)的火用损失分布,指出系统中最大火用损失过程为煤气化、燃气轮机燃烧和空分过程。同时,揭示了系统随不同空气整体化和氮气回注的规律。这些研究可以指导下一代IGCC系统的改进。
先张法预应力空心板火损评定方法及处治对策  [PDF]
童浩,季晓燕,赵佳军,李捷,郭涛
公路交通科技 , 2012,
Abstract: 火灾对先张法预应力空心板的安全性、耐久性存在非常不利的影响,详细阐述了火灾事故的处置思路和具体方法。研究提出综合采用颜色判别法、损伤程度判别法以及空心板内部温度场有限元分析法,以便更准确地判别火灾后结构的内部损伤。研究结果表明,火灾高温灼烧后混凝土强度严重下降,结构工作性能降低甚至丧失。通过对火损后结构表观状况和各类重要指标劣化的检测、火灾时结构表面温度推算、结构内部温度场模拟分析,研究得出判别内部损伤深度情况的方法,对损伤程度不同的板梁分别提出了保留利用、加固或拆除等相应处置措施。
Page 1 /100
Display every page Item


Home
Copyright © 2008-2017 Open Access Library. All rights reserved.