oalib
Search Results: 1 - 10 of 100 matches for " "
All listed articles are free for downloading (OA Articles)
Page 1 /100
Display every page Item
Lentes intraoculares amarillas Yellow intraocular lens  [cached]
V.M. Asensio-Sánchez
Archivos de la Sociedad Espa?ola de Oftalmología , 2009,
Abstract:
Lentes intraoculares con filtros para luz azul
Cristóbal,JA; Sierra,J; Martín,J; Rodríguez,NA; Ascaso,J;
Archivos de la Sociedad Espa?ola de Oftalmología , 2005, DOI: 10.4321/S0365-66912005000400008
Abstract: purpose: to evaluate if a sn60at ?natural?? iol (alcon) with impruv filter ?(alcon) offers any advantage in patients having cataract surgery, as compared with acrysof sa60? iol (alcon). methods: this was a prospective analytical study. we studied sixty-four eyes from 32 patients with cataracts. after a random assignment, phacoemulsification with the implant was performed using the acrysof sn60at tinted lens in one eye and acrysof sa60 in the other. a variety of variables was subsequently assessed: contrast sensitivity with a csv 1000e test, colour perception through a farnsworth 25 test and subjective measures by a patient survey. differences between the groups were assessed statistically. results: the contrast sensitivity results were obtained for 3, 6, 12 and 18 cycles per degree (cpd) frequencies under scotopic conditions, with better results obtained following the use of sn60at: 0.75 (csv 1000e test units) for 3 cpd, 0.86 for 6 cpd, 0.54 for 12 cpd and 0.35 for 18 cpd. the differences were statistically significant between the two groups for 3 cpd and 6 cpd. a total of 62.5% of patients using a tinted lens and 50% with sa60 achieved good results in the farnsworth test; 12.5% and 21% had fair results and 25% and 28.1% respectively had poor results. conclusions: we obtained an improvement in favour of the tinted lens for all frequencies, with this being statistically significant at lower frequencies (3 and 6 cpd). no significant differences in the farnsworth test performance or in the patient survey were found. the tinting provided by the impruv filter brings an increase in contrast sensitivity without affecting colour perception.
Lentes intraoculares con filtros para luz azul Intraocular lenses with blue light filter  [cached]
JA Cristóbal,J Sierra,J Martín,NA Rodríguez
Archivos de la Sociedad Espa?ola de Oftalmología , 2005,
Abstract: Objetivo: Comparar si la lente intraocular SN60AT Natural (Alcon), con filtro IMPRUV (Alcon), aporta mejorías en la visión de los pacientes intervenidos de catarata con respecto a la Acrysof SA60 (Alcon). Métodos: Estudio prospectivo analítico, sobre treinta y dos pacientes (64 ojos) que presentaban catarata. Se realizó facoemulsificación con implante, tras un método de asignación aleatorio, de una lente Acrysof SN60AT (Natural) en un ojo y en el ojo contralateral de una Acrysof SA60. Determinamos diferencias entre ambas lentes para las variables de sensibilidad al contraste (CSV 1000E . Vistech), percepción de los colores (Farnsworth 25) y una valoración subjetiva por el paciente a través de una encuesta. Se realizó un estudio estadístico para comparación de ambas muestras. Resultados: Los resultados de sensibilidad al contraste se obtuvieron para las frecuencias de 3, 6, 12 y 18 ciclos por grado (cpd) en condiciones escotópicas obteniendo una diferencia a favor de SN60AT de 0,75 (unidades de test del CSV 1000E) para 3 cpd, 0,86 para 6 cpd, 0,54 para 12 cpd y 0,35 para 18 cpd, siendo estadísticamente significativa esta diferencia en el caso de las dos primeras. Un 62,5% de pacientes con lente tintada y un 50% de los pacientes con SA60 realizaron el test de Farnsworth 25 con buen resultado, un 12,5% y un 21% regular, y un 25% y un 28,1% mal. Conclusiones: Hemos obtenido una mejora para todas las frecuencias a favor de la lente tintada, siendo estadísticamente significativas para las frecuencias bajas (3 y 6 cpd.) No hemos apreciado diferencias significativas en la realización del test de Farnsworth, ni el paciente las refiere a través del test subjetivo. La tinción que supone la adición del filtro IMPRUV (Alcon), conlleva un aumento en la sensibilidad al contraste sin consecuencias para la percepción de los colores. Purpose: To evaluate if a SN60AT Natural IOL (Alcon) with IMPRUV filter (Alcon) offers any advantage in patients having cataract surgery, as compared with Acrysof SA60 IOL (Alcon). Methods: This was a prospective analytical study. We studied sixty-four eyes from 32 patients with cataracts. After a random assignment, phacoemulsification with the implant was performed using the Acrysof SN60AT tinted lens in one eye and Acrysof SA60 in the other. A variety of variables was subsequently assessed: contrast sensitivity with a CSV 1000E test, colour perception through a Farnsworth 25 test and subjective measures by a patient survey. Differences between the groups were assessed statistically. Results: The contrast sensitivity results were
Implante de lentes intraoculares tóricas Acrysof en cirugía de la catarata Acrysof toric intraocular lens implantation in cataract surgery
J. Zarranz-Ventura,J. Moreno-Monta?és,J. Caire y González-Jáuregui,E. de Nova Fernández-Yá?ez
Archivos de la Sociedad Espa?ola de Oftalmología , 2010,
Abstract: Propósito: Valorar los resultados a medio plazo del implante de lentes intraoculares tóricas Acrysof en 54 pacientes (54 ojos). Método: Los parámetros analizados fueron mejor agudeza visual sin corrección (AVSC) y agudeza visual mejor corregida (AVMC), astigmatismo preoperatorio y residual postoperatorio, y rotación de la lente globalmente y en cada modelo de lente intraocular empleado. Resultados: A los 2 meses del seguimiento, la AVSC media total fue de 0,83 (DS: 0,14) Snellen, estando el 73,9% de ellos con AVSC >0,8 y el 32,6% en 1,0. La AVMC fue de 0,94 (DS: 0,10). El astigmatismo medio preoperatorio fue de -2,25 dioptrías (D) (DS: 0,78), siendo el astigmatismo medio postoperatorio total de -0,32 D (DS: 0,56), con diferencia estadísticamente significativa entre ambos grupos (p<0,001). Desglosado por tipo de lente el astigmatismo fue -0,1 para las lentes T3, -0,27 D para las T4, y -0,43 para las T5, sin diferencias significativas entre los grupos estudiados (p=0,483). La rotación media del eje de la LIO respecto al eje previsto fue de 3,87±3,25 grados, con rotación menor a 10o en el 91,6% de las LIO implantadas. Discusión: Las lentes tóricas modelo Acrysof T3, T4 y T5 permiten corregir el astigmatismo preoperatorio con un porcentaje elevado de éxito en lo que a AVSC y astigmatismo residual postoperatorio se refiere, con un mínimo grado de rotación de la lente a los 2 meses. Aim: To assess the medium term outcomes of Acrysof toric intraocular lens implantation in 54 patients (54 eyes). Methods: Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), preoperative astigmatism, residual postoperative astigmatism, and global average and model-specific intraocular lens (IOL) rotation grade were analyzed. Results: At 2-months of follow-up,the mean UCVA was 0.83 (SD: 0.14) Snellen scale, with 73.9% of the patients >0.8, and 32.6% with 1.0. Mean BCVA achieved was 0.94 (SD: 0.10). Mean preoperatory astigmatism was -2.25 diopters (D) (SD: 0.78), and mean postoperative astigmatism was -0.32 D (SD: 0.56), with significant differences between both groups (p<0.001). Model-specific mean residual astigmatism was -0.1 D for T3, -0.27 D for T4 and -0.43 D for T5, without significant differences between the three models (p=0.483). Mean IOL-axis rotation grade was 3.87±3.25 degrees, with 91.6% of implanted lens within 10o of predicted axis. Discussion: T3, T4 and T5 Acrysof Toric intraocular lenses can correct preoperative astigmatism with a high success rate in terms of UCVA, and residual postoperative astigmatism, with minimum IOL-rotation grade at 2 m
Estudio clínico comparativo de los resultados visuales en dos lentes intraoculares bifocales Comparative clinical study of visual results between two different types of bifocal intraocular lenses  [cached]
A Lleó Pérez,L Alonso Mu?oz,JA Sanchís Gimeno,MA Marcos Jorge
Archivos de la Sociedad Espa?ola de Oftalmología , 2003,
Abstract: Introducción: Comparar los resultados visuales tras cirugía de cataratas con implante de dos tipos de lentes intraoculares (LIO) bifocales: el modelo 811E (Pharmacia), y el modelo MF4 (Ioltech). Métodos: Para ello realizamos un estudio prospectivo en 99 pacientes intervenidos de cataratas mediante facoemulsificación con posterior implante de LIO bifocales. En 47 pacientes se implantó el modelo 811E, y en 52 pacientes se implantó el modelo MF4. Se valoraron agudezas visuales (AV) (lejos y cerca) y refracción postoperatoria tras un periodo de seguimiento de 6 meses. La satisfacción de los pacientes se evaluó mediante un cuestionario. Resultados: No se observaron diferencias entre ambos tipos de lentes al valorar la AV para lejos sin corrección, siendo 0,63 (D.E.: 0,2) para la 811E y 0,58 (D.E.: 0,16) para la MF4 (p=0,17). Por el contrario, se observaron diferencias significativas al valorar la AV media para lejos con corrección, siendo 0,86 (D.E.: 0,1) para la 811E y 0,77 (D.E.: 0,12) para la MF4 (p=0,01), y la AV media para cerca sin corrección, siendo J2,00 (D.E.: 1,16) para la 811E y J2,48 (D.E.: 0,83) para la MF4 (p=0,021). El porcentaje de satisfacción de los pacientes fue similar en ambos tipos de LIOs, siendo respectivamente del 78% (811E) y del 73,4% (MF4). Conclusiones: Nuestros resultados muestran una superioridad de las lentes difractivas bifocales sobre las lentes refractivas bifocales en la agudeza visual corregida para lejos y en la agudeza visual de cerca con la corrección de lejos. Las complicaciones postoperatorias y el grado de satisfacción fueron similares para ambos modelos. Purpose: To compare visual results after cataract surgery in patients who underwent bilateral implantation of two different types of bifocal intraocular lenses: the model 811E (Pharmacia), and the model MF4 (Ioltech). Methods: This prospective study comprised 99 patients who underwent phacoemulsification with bifocal IOL implantation. The model 811E was implanted in forty-seven eyes of 47 patients (group I) and the model MF4 in fifty-two eyes of 52 patients (group II). Visual acuity (distance and near), complications, and adverse events were measured. The postoperative follow-up in all patients was of 6 months. Patient satisfaction was also valued using a questionnaire. Results: There was no significant difference in uncorrected distance visual acuity between both groups, which was respectively 0.63 (S.D.: 0.2) for group I and 0.58 (S.D.: 0.16) for group II (p=0.17). Nonetheless a significant difference was found when measuring corrected distance visual acuity, whi
Estudio experimental en ojos de cerdo sobre el desplazamiento de las lentes intraoculares subluxadas tras una capsulotomía láser Nd: YAG Experimental study of pig dislocated intraocular lens shift after Nd: YAG laser capsulotomy
J. Colomé Campos,P. Romero-Aroca,Ll. Quevedo Junyent,I. Martínez-Salcedo
Archivos de la Sociedad Espa?ola de Oftalmología , 2011,
Abstract: Objetivos: Valorar en los ojos del cerdo el desplazamiento de las lentes intraoculares subluxadas respecto a la posición inicial tras la realización de una capsulotomía láser Nd: YAG. Métodos: Se utilizaron 15 ojos de cerdo a los que les realizamos una cirugía extracapsular de cristalino transparente. Tras la introducción de una lente intraocular (LIO) dentro del saco capsular se provocó una diálisis zonular hasta objetivar un desplazamiento de la LIO de un valor mínimo de 4mm. Efectuamos una capsulotomía láser Nd: YAG en forma de cruz en los 3,5mm centrales del eje óptico a elevadas energías. Se midió el desplazamiento final de la LIO con la ayuda de una regla milimetrada. Resultados: En ninguno de los ojos estudiados se objetivó un desplazamiento significativo en relación a la situación inicial. Conclusiones La capsulotomía láser Nd: YAG en LIOs subluxadas se presenta para ojos estáticos como una maniobra segura a corto plazo. Objectives: To evaluate the movement from their initial set position of subluxated intraocular lenses (IOL) in pig eyes following Nd: YAG laser capsulotomy. Methods: An extracapsular surgical intervention of the transparent crystalline lens was performed on 15 pig eyes. After the introduction of an intraocular lens into the capsular sac, a zonular dialysis was carried out to observe the shift of the IOL. We carried out a high intensity Nd: YAG laser capsulotomy in a 3.5mm cross shape in the central optical axis and then measured the final displacement of the IOL using a millimetre ruler. Results: We did not observe a significant shift of the lens in any of the eyes studied. Conclusions: Nd: YAG laser capsulotomy is a safe short-term operation for static and subluxated intraocular lenses.
Resultados del implante múltiple de lentes intraoculares en la cirugía de catarata en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer" Results of the multiple intraocular lenses implantation in the cataract surgery performed at "Ramón Pando Ferrer" Cuban Institute of Ophthalmology  [cached]
Eric Montero Díaz,Armando Capote Cabrera,Eneida Pérez Candelaria,Imalvet Santiesteban García
Revista Cubana de Oftalmolog?-a , 2010,
Abstract: OBJETIVO: Valorar los resultados visuales de los pacientes operados con la técnica de piggy back o implantes múltiples de lentes intraoculares. MéTODOS: Se realizó un estudio descriptivo retrospectivo de corte transversal en el que se tomaron 32 ojos de 30 pacientes del universo operado de catarata, con la técnica antes descrita, en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer", en el período comprendido entre enero de 2000 hasta diciembre de 2006. Fueron evaluadas algunas variables demográficas, como edad y sexo, así como agudeza visual y refracción preoperatorio y posoperatoria con cristales y sin ellos. Reportamos las complicaciones transquirúrgicas y posquirúrgicas asociadas a las diferentes técnicas quirúrgicas empleadas para la extracción del cristalino. RESULTADOS: La edad promedio obtenida fue mayor de 50 a os, y predominó el sexo femenino. Parte de los pacientes tuvieron una agudeza visual corregida superior a 20/40. La complicación más frecuente fue la opacidad de la cápsula posterior y solo en la tercera parte de los pacientes se obtuvo una buena corrección refractiva. CONCLUSIONES: La técnica de piggy back permitió la recuperación de cuatro líneas en la cartilla de Snellen en la agudeza visual corregida, mientras que en la agudeza visual sin corrección solo aumentó en dos líneas. Se encontró igual número de pacientes hipocorregidos y bien corregidos. OBJECTIVE: To asses the visual results of patients operated on by piggy back technique or multiple implantation of intraocular lenses METHODS: A retrospective cross-sectional descriptive study was conducted in 32 eyes from 30 patients operated on from cataract, using the above-mentioned technique, at "Ramon Pando Ferrer" Cuban Institute of Ophthalmology in the period January 2000 through December 2006. Some demographic variables as age and sex as well as visual acuity and preoperative and postoperative refraction with/without lenses were evaluated. Trans-surgical and post-surgical complications associated with the various surgical techniques for the crystalline extraction were reported. RESULTS: Average age was 50 years, being the females predominant. One part of the patients had corrected visual acuity over 20/40. The most frequent complication was posterior capsule opacity and only one third of patients showed good refractive correction. CONCLUSIONS: Piggy back technique allowed recovering four lines in corrected visual acuity in Snellen′s chart whereas uncorrected visual acuity increased two lines only. The number of hypocorrected and well-corrected patients was the same.
Microscopic analysis of opacification in Ioflex hydrophilic acrylic intraocular lenses Análise microscópica da opacifica o de lentes intraoculares acrílicas hidrofílicas Ioflex  [cached]
Bruna Vieira Ventura,Marcelo Ventura,Wagner Lira,Camila Vieira Ventura
Revista Brasileira de Oftalmologia , 2012, DOI: 10.1590/s0034-72802012000300002
Abstract: Five cases of intraocular lens (IOL) opacification in patients implanted with the Mediphacos Ioflex IOL are described. Clinical data in each case was obtained from the patient's medical record. The five explanted IOLs underwent gross and light microscopic analysis. Selected lenses were processed for further evaluation and multiple sagittal cuts were stained with the alizarin red and von Kossa methods. Light microscope analysis confirmed the presence of deposits on and within the lens, which stained positive for calcium. The reason why calcification has occurred in these cases remains unclear, but surgeons should be aware of this potential late postoperative complication. Cinco casos de opacifica o de lente intraocular (LIO) em pacientes implantados com a LIO Ioflex da Mediphacos s o descritos. Os dados clínicos dos pacientes foram obtidos a partir dos prontuários médicos. As cinco LIOs explantadas foram enviadas para análise macroscópica e sob microscopia óptica. Algumas lentes foram processadas para análise adicional e múltiplos cortes sagitais foram corados pelos métodos de vermelho de alizarina e von Kossa. A análise sob microscopia óptica confirmou a presen a de depósitos na superfície e no corpo da lente, que coraram positivamente para cálcio. A raz o pela qual a calcifica o ocorreu nestes casos permanece obscura. Entretanto, cirurgi es devem estar atentos para esta potencial complica o tardia.
Novidades na cirurgia de catarata: lentes intraoculares asféricas  [cached]
Newton Kara-José Junior
Revista Brasileira de Oftalmologia , 2009, DOI: 10.1590/s0034-72802009000400001
Abstract:
Hypnosis-associated blue-tinted vision: a case report
Ran D Anbar, Aaron D Savedoff
BMC Ophthalmology , 2005, DOI: 10.1186/1471-2415-5-28
Abstract: The patient reported blue-tinted vision when he used hypnosis on an almost daily basis for seven years. The visual change typically occurred when he was relaxed. Moreover, a concurrent erection in the absence of sexual thoughts usually was present. The other three individuals reported blue-tinted vision after learning how to use hypnosis for relaxation as part of a group hypnosis instruction.The blue-tinted vision experienced by the individuals in this report may be the result of an hypnosis-induced primary change in cognitive processing. Additionally, as the relaxing effect of hypnosis can be associated with a reduction in blood pressure and increased blood flow, hypnosis-associated blue-tinted vision also may be related to retinal vasodilation.Self-hypnosis has been taught routinely at the SUNY Upstate Medical University Pediatric Pulmonary Center for treatment of pulmonary symptoms thought to be amenable to psychological therapy [1]. Patients who have benefited from hypnosis instruction include those with asthma, cystic fibrosis (CF), habit cough, shortness of breath, and vocal cord dysfunction [1,2].Our understanding of the nature of hypnosis is contested, and rapidly evolving [1]. In practice, hypnosis can be defined as an altered state of consciousness during which a therapeutic goal can be achieved as a result of suggestions made by a therapist or self-suggestions given by a patient [1]. The state of hypnosis is a natural mental state that can be achieved, for example, by children engaged in imaginary play, or when students become bored and imagine themselves engaged in an activity elsewhere.After being taught to use hypnosis for relaxation by a physician from our Center, four individuals, including a patient with CF, reported development of blue-tinted vision. Based on a search of the literature, we believe this is the first published report of hypnosis-associated blue-tinted vision.The patient was a 15-year-old with mild CF who was non-adherent to his presc