oalib
Search Results: 1 - 10 of 100 matches for " "
All listed articles are free for downloading (OA Articles)
Page 1 /100
Display every page Item
Tratamiento de lixiviados por oxidación Fenton Treating leachate by Fenton oxidation  [cached]
Méndez Novelo Roger Iván,García Reyes Refugio Bernardo,Castillo Borges Elba René,Sauri Riancho María Rosa
Ingeniería e Investigación , 2010,
Abstract: Los lixiviados son el resultado de la percolación de líquidos a través de los desechos sólidos en proceso de estabilización. La complejidad del tratamiento de los lixiviados se deriva de que su composición es altamente tóxica y variable y debido al suelo altamente permeable de la península de Yucatán, México representan un peligro alto para la salud. Se presentan los resultados de aplicar el proceso Fenton a los lixiviados del relleno sanitario de la ciudad de Mérida. El proceso Fenton consiste en tratar la carga contaminante con una combinación de H2O2 y FeSO4 en condiciones ácidas. Se determinaron el tiempo óptimo de reacción, los valores óptimos de pH y dosis de reactivo Fenton, así como las dosis óptimas para el postratamiento coagulación – flo- culación. Las condiciones y dosis óptimas del proceso de oxidación fueron: tiempo de contacto de 20 minutos, un valor de pH i-2+ igual a 4, concentraciones de H2O2 de 600 mg/l y Fe de 1,000 mg/l. Los porcentajes de remoción promedio de materia orgánica, medida como DQOs, fue de 78%, y medida como COT, del 87%. Leachates are formed from liquids, mainly rainwater, percolating through solid wastes during stabilisation. Their composition is variable and highly toxic; leachate treatment is therefore a complex task. Leachates represent a high risk to health due to the Yucatan Peninsula’s highly permeable soil. The results are presented from applying the Fenton process to treating leachate from the sanitary Merida landfill, Yucatan, Mexico. The Fenton process consists of treating the contaminant load with an H2O2 and FeSO4 combination in acidic conditions. Optimal reaction time, pH value, Fenton reagent dose, post treatment coagulation – flocculation doses and increased biodegradability index were all determined. Optimal oxidation conditions and doses were 202+ minute contact time, 4 pH, 600 mg/L H2O2 concentration and 1,000 mg/L Fe. Average organic matter removal rate, measured as CODS and TOC, were 78% and 87% respectively. The biodegradability index increased from 0.07 to 0.11 during the Fenton process and up to 0.13 when the Fenton process was followed by coagulation-flocculation.
COMPARACIóN DE CUATRO TRATAMIENTOS FISICOQUíMICOS DE LIXIVIADOS  [cached]
Roger Iván MéNDEZ NOVELO,Elba René CASTILLO BORGES,María Rosa SAURI RIANCHO,Carlos Alberto QUINTAL FRANCO
Revista internacional de contaminación ambiental , 2009,
Abstract: Se presentan los resultados de cuatro tratamientos fisicoquímicos aplicados a los lixiviados del relleno sanitario de la ciudad de Mérida: coagulación-floculación, flotación, adsorción y oxidación Fenton. Los procesos coagulación-floculación y flotación consisten en la remoción de partículas suspendidas mediante la adición de sustancias químicas (coagulantes). Ambos resultaron poco eficientes dado que los lixiviados estudiados poseen bajas concentraciones de sólidos suspendidos. No se encontraron en la literatura experiencias exitosas de estos tratamientos y, en concordancia, se comprobó que los lixiviados de los rellenos sanitarios poseen bajas concentraciones de sólidos suspendidos, lo cual explica la baja eficiencia de remoción. La mayor parte de las partículas suspendidas de los lixiviados estudiados tenían tama os en el rango de 0 a 75 m, con una media de 23 m, los cuales corresponden a partículas coloidales que dan color al lixiviado. La remoción de este tipo de partículas se realiza a valores bajos de pH. Por este motivo, las mejores remociones fueron de 40 % a valores de pH < 2 para el proceso coagulación-floculación y de 37 % a pH 2 para la flotación. Con el proceso de adsorción se pueden eliminar sólidos suspendidos y disueltos, por lo que se pueden obtener mejores remociones que con los procesos de coagulación-floculación y flotación, en los que sólo se remueven sólidos suspendidos. No obstante, resulta un proceso costoso debido a la necesidad de regenerar el carbón activado. En la prueba de adsorción, las eficiencias de remoción de la demanda química de oxígeno (DQO) se redujeron de 60 a 30 % durante las primeras 80 horas cuando el tiempo de retención fue de ocho horas, y durante las primeras 60 horas cuando el tiempo de retención fue de cuatro horas. En el proceso de oxidación, la carga contaminante se trata con una combinación de peróxido de hidrógeno y sulfato ferroso (reactivo Fenton), típicamente a presión atmosférica y temperatura entre 20 y 40 oC. Las condiciones óptimas del reactivo Fenton se obtienen a valores ácidos de pH y con ellas se pueden alcanzar altas remociones de los contaminantes orgánicos. Las condiciones y dosis óptimas del proceso de oxidación fueron: tiempo de contacto 20 minutos, pH 4, concentraciones de H2O2 de 600 mg/L y Fe2+ de 1000 mg/L. Las mejores remociones alcanzadas fueron de 78 % para la DQO y 87 % para el carbón orgánico total (COT), por lo que resultó el tratamiento más eficiente entre los probados en el estudio.
Tratamiento de lixiviados por oxidación Fenton
Méndez Novelo,Roger Iván; García Reyes,Refugio Bernardo; Castillo Borges,Elba René; Sauri Riancho,María Rosa;
Ingeniería e Investigación , 2010,
Abstract: leachates are formed from liquids, mainly rainwater, percolating through solid wastes during stabilisation. their composition is variable and highly toxic; leachate treatment is therefore a complex task. leachates represent a high risk to health due to the yucatan peninsula′s highly permeable soil. the results are presented from applying the fenton process to treating leachate from the sanitary merida landfill, yucatan, mexico. the fenton process consists of treating the contaminant load with an h2o2 and feso4 combination in acidic conditions.optimal reaction time, ph value, fenton reagent dose, post treatment coagulation - flocculation doses and increased biodegradability index were all determined. optimal oxidation conditions and doses were 20 minute contact time, 4 ph, 600 mg/l h2o2 concentration and 1,000 mg/l fe2+. average organic matter removal rate, measured as cods and toc, were 78% and 87% respectively. the biodegradability index increased from 0.07 to 0.11 during the fenton process and up to 0.13 when the fenton process was followed by coagulation-flocculation.
Empleo del reactivo de Fenton para la degradación del colorante Tartrazina  [cached]
Joan Amir Arroyave Rojas,Luis Fernando Garcés Giraldo,Julieta Mejía Trujillo
Revista Lasallista de Investigación , 2009,
Abstract: Objetivo. Evaluar la degradación del colorante Tartrazina empleando la reacción de Fenton. Se busca implementar una tecnología de oxidación avanzada para la remoción del colorante Tartrazina, ampliamente utilizado en la industria de alimentos en el medio local, nacional e internacional. Materiales y métodos. Se empleó un dise o experimental factorial aleatorizado con un reactor compuesto por una cuba de vidrio como reservorio, para el almacenamiento de la muestra problema y el lugar para la reacción de degradación; adicionalmente, se dispuso de un sistema interno de mezcla para mantener la solución homogénea en el periodo de experimentación, el cual se determinó en dos horas. Se utilizó una concentración inicial de 100 mg/L del colorante Tartrazina y se mantuvo la solución a un pH igual a 3.0. La degradación del colorante, se determinó mediante el empleo de la espectrofotometría UV/Visible a una longitud de onda de 425 nm. Resultados. Se logró la remoción y degradación del colorante Tartrazina empleando diferentes combinaciones de oxidación del reactivo de Fenton, sin embargo, el mejor porcentaje de remoción fue de 99,3 % mediante la combinación de 25 mg/L de Fe 3+ y 0,4 %v/v del agente oxidante peróxido de hidrógeno. Conclusión. La reacción de Fenton es adecuada y logra elevados porcentajes de remoción y degradación del colorante azo Tartrazina.
Empleo del reactivo de Fenton para la degradación del colorante Tartrazina
Arroyave Rojas,Joan Amir; Garcés Giraldo,Luis Fernando; Mejía Trujillo,Julieta;
Revista Lasallista de Investigación , 2009,
Abstract: objective. to evaluate the degradation of tartrazine dye by using the fenton's reagent. we aim to implement an advanced oxidation technology in order to remove the tartrazine dye, which is widely used in food industry locally, nationally and internationally. materials and methods. a randomized factorial experimental design was used, with a reactor composed of a glass recipient as a reservoir to store the problem sample and the reaction place for the degradation. additionally, an internal mixing system was arranged to keep the solution homogeneous during the experimental period (two hours). an initial 100 mg/l concentration of tartrazine was used, and the solution was kept at a 3.0 ph level. the dye's degradation was determined by the use of uv/visible spectrophotometry at a 425 nm wavelenghht. results. the removal and degradation of the tartrazine dye was achieved using different combinations of the fenton's reagent's oxidation. the best removal percentage was, however, 99.3 % of the dye, by the combination of the fenton's reaction corresponding to 25 mg/l of fe3+ and 0,4 %v/v of the hydrogen peroxide oxidation agent. conclusion. fenton's reaction is adequate and achieves high removal and degradation percentages of the azo tartrazine dye.
Degradación y mineralización del colorante rojo punzó empleando el reactivo de Fenton
Arroyave Rojas,Joan Amir; Rodríguez Gaviria,Edna Margarita; Barón Aristizábal,Carlos Alberto; Moreno Salazar,Cristian Camilo;
Producción + Limpia , 2012,
Abstract: introduction. this paper introduces the use of an advanced oxidation technique to remove and mineralize the ponceau red dye, which is widely used in food industries locally, nationally and internationally. objective. to evaluate the degradation and the mineralization of the ponceau red dye, by the use of the fenton reagent. materials and methods. a reagent consisting of a glass bucket which served as a reservoir for the sample and for the degradation. additionally, an internal mixture system was installed to keep the solution homogeneous during the experimentation period, which took two (2) hours. an initial concentration of 100 mg/l of the ponceau red dye was used, and the solution to be treated was kept as a ph of 3,0. the degradation of the dye was determined by the use of uv/visible spectrophotometry at a 505 nm. of wavelength and the mineralization was determined by the appearing of sulfates as a by-product of the degradation at 420nm of wavelength, according with the sulfates parameter taken from the normalized methods to analyze water and waste water. results. the degradation and the mineralization of the ponceau red dye was achieved by the use of several combinations of the fenton reagent. additionally, the best percentages of removal and mineralization of the dye obtained were 97,8 and 86,2%, respectively, by means of the combination of the fenton reaction that corresponded to 10 mg/l of fe 3+and 0,10 %v/v of the oxidation agent hydrogen peroxide. conclusion. the fenton reaction is adequate to degrade and mineralize the ponceau red dye and reaches high removal and mineralization percentages of that dye.
Tratamiento anaerobio de lixiviados en reactores UASB  [cached]
Patricia Torres Lozada,Jenny Alexandra Rodríguez,Luz Edith Barba,Adriana Morán
Ingeniería y Desarrollo , 2005,
Abstract: El propósito de este estudio fue evaluar la aplicación de Tecnología Anaerobia en un reactor UASB a escala laboratorio, para la degradación biológica de los lixiviados provenientes de un sector del vertedero en que se disponen los residuos sólidos urbanos de una ciudad de 2.4 millones de habitantes. El reactor fue operado con un TRH constante de 24 horas y con COV entre 6,0 y 32 kgDQO/m3.día, variando la concentración de DQO entre 3567 y 59350 mg/L. Con el ajuste del pH y la concentración de fósforo en el sustrato, fue posible alcanzar eficiencias de remoción de DQO mayores al 90%. Estos resultados confirman la factibilidad de uso de esta tecnología para el tratamiento de esta agua residual.
Lixiviados de biosólidos sobre la biota dulceacuícola  [PDF]
Francisco José Flores Tena,Lizbeth Flores Pardavé,Iris del Carmen Valenzuela Cárdenas,Eduardo Andrés Flores Salinas
Investigación y Ciencia de la Universidad Autónoma de Aguascalientes , 2010,
Abstract: El objetivo de este estudio es conocer los efectos que producen los lixiviados de los biosólidos sobre diversos representantes de la biota dulceacuícola. Los efectos sobre el crecimiento o la mortalidad(CL50) en las diferentes especies se evalúan a través de diversos bioensayos. Nannochloris oculata resultó afectada en su crecimiento por concentraciones mayores a 500 ppm de lixiviados.Las CL50, a las 48 h., para las especies de la fauna fueron 8.6%, 42.4% y >80% para Oreochromis niloticus, Lecane quadridentata y Limnodrilus hoffmeisteri, respectivamente. Los drenajes del suelo adicionado con biosólidos también afectaron a N. oculata, mientras que las CL50, a las 48 h; para la fauna acuática fueron 90 t/ha, 206t/ha y 432 t/ha para las especies ya mencionadas.Las concentraciones obtenidas en los bioensayos son altas y difícilmente se presentarán en la naturaleza, a menos que por descuido en el manejo de los biosólidos se concentren loslixiviados en el campo, lleguen y permanezcan en los ecosistemas dulceacuícolas.
Tratamiento de aguas residuales mixtas e industriales utilizando el reactivo de Fenton electrogenerado  [cached]
Alfonso Durán Moreno,Juan Alberto Hernández Parra,Carlos E. Roth Carranza,Carmen Durán de Bazúa
Tecnología, Ciencia, Educación , 2003,
Abstract:
Modelización de transporte reactivo: aplicación a la dedolomitizacion  [cached]
Ayora, C.,Taberner, C.,Samper, J.
Estudios Geologicos , 1994, DOI: 10.3989/egeol.94505-6331
Abstract: The replacement of dolomite with calcite (dedolomitization) has been analyzed by means of two numerical models of reactive transports The results of successive calculations under different scenarios have been compared with the observations made on the dedolomites developed on the Triass c strata from Prades (Tarragona, Spain). The model based on the local equilibrium assumption for water-rock interaction does not predict the development of the porosity associated to the replacement. The model based on kinetic laws for mineral disolution and precipitation does predict the observed proportions of calcite, dolomite and porosity. The result of modeling under kinetic laws is sensitive to parameters such as the flow velocity, the chemical composition of the recharge water and the reactive surface of the minerals. The replacement and associated porosity is only formed for infiltration flows higher than 100 mm/year. The water has a neutral to slightly alkaline pH, far from equilibrium with carbonates and the atmosphere. The calcium concentrations must be one order of magnitude higher than the average of surficial waters, probably due to sulfate dissolution. The reactive surface 01' dolomite has been estimated from a simple geometric model of fractures, whereas that of calcite has been inferred from calculations based on nucleation and crystal growth theory. The reactive surface of calcite appears to be several orders of magnitude lower than that of dolomíte, im agreement with.what is required for reactive transport calculations to generate porosity. The dedolomltization and associated porosity takes place in the first meter of aquifers, whereas downstream the replacement vanishes and does not create porosity. Se han utilizado dos modelos numéricos de transporte reactivo para analizar el proceso de dedolomitización: reemplazamiento de dolomita por calcita debido a la infiltración de agua en un estrato dolomítico. Los resultados de sucesivos cálculos en diferentes escenarios se han comparado con observaciones preliminares en las carniolas desarrolladas en las dolomías del Triásico de Prades (Tarragona). El modelo basado en la hipótesis de equilibrio local entre el agua y la roca no predice el desarrollo de porosidad asociadad reemplazamiento. En cambio, el modelo basado en leyes cinéticas de disolución y precipitación mineral es capaz de predecir las proporciones de dolomita, calcita y porosidad observadas. El resultado de la modelización mediante leyes cinéticas es sensible a determinados parámetros como la velocidad del flujo, la composición química del agu
Page 1 /100
Display every page Item


Home
Copyright © 2008-2017 Open Access Library. All rights reserved.