oalib
Search Results: 1 - 10 of 100 matches for " "
All listed articles are free for downloading (OA Articles)
Page 1 /100
Display every page Item
Composi??o química de macrófitas aquáticas flutuantes utilizadas no tratamento de efluentes de aqüicultura
Henry-Silva, G.G.;Camargo, A.F.M.;
Planta Daninha , 2006, DOI: 10.1590/S0100-83582006000100003
Abstract: the purpose of this work was to evaluate the chemical composition of two floating aquatic macrophytes (eichhornia crassipes and pistia stratiotes) used in the treatment of aquaculture wastewater and to infer their potential use as biomass. e. crassipes showed the highest contents of calcium (1.51%), magnesium (3,916.67 mg kg-1), manganese (1,233.33 mg kg1), zinc (81.83 mg kg-1), iron (5,425.00 mg kg-1) and copper (25.83 mg kg-1). p. stratiotes showed the highest contents of ash (18.95%), phosphorus (0.38%), nitrogen (2.40%), crude protein (15.02%) and amino acids, except for aspartic acid and tryptophan.
METODOLOGIA ALTERNATIVA PARA O TRATAMENTO DE EFLUENTES DE INDúSTRIA DE CELULOSE KRAFT
S?nia Maria Bitencourt Frizzo,Maria Cládis Mezzomo da Silva,Ayrton Figueredo Martins,Celso Edmundo Foelkel
Ciência Florestal , 2013,
Abstract: S o descritos procedimentos para o tratamento terciário dos efluentes da Indústria Riocell S.A. (Guaíba, RS), com base no reaproveitamento de resíduos sólidos e de excedentes de processo químico. As amostras de efluente foram caracterizadas em relac o a sua cor aparente e ao seu teor em organo-halogenados sendo após, submetidas a polimento com dois coagulantes/floculantes distintos, utilizando resíduos sólidos de processo ("dreg","grit", cinzas) e carv o ativo como coajuvantes. Uma apreciável redu o na cor aparente e no teor de organo-halogenados dos efluentes finais foi observada, bem como uma economia no gasto com coagulantes/floculantes.
O processo eletroquímico como alternativa para o tratamento de efluentes cianídricos  [cached]
Dutra Achilles Junqueira Bourdot,Sobral Luiz Gonzaga Santos,Lemos Flávio de Almeida,Santos Fábio Henrique Silva dos
Rem: Revista Escola de Minas , 2002,
Abstract: Embora o cianeto seja um reagente amplamente empregado na lixivia o de metais preciosos e no acabamento superficial de certos metais, sua elevada toxicidade faz com que o uso de tecnologias eficientes no tratamento dos efluentes desses processos seja primordial. Existem diversas técnicas disponíveis para o tratamento de efluentes industriais contendo cianeto, contudo os métodos mais empregados baseiam-se na oxida o química do cianeto a uma espécie menos tóxica, o cianato, que se hidrolisa produzindo os íons am nio e bicarbonato, além de uma lama contendo hidróxidos de metais pesados, quando presentes no efluente. Entre as técnicas mais recentes para o tratamento de efluentes contendo cianeto, a oxida o eletroquímica apresenta algumas vantagens, como a possibilidade de recupera o dos metais complexados pelo cianeto, além de n o necessitar de reagentes químicos adicionais, sendo perfeitamente capaz de atender às exigências dos órg os ambientais. Esse trabalho apresenta uma compara o entre os diversos processos de tratamento de efluentes contendo cianeto, com ênfase no processo eletroquímico, e também uma revis o sobre estado atual dessa tecnologia.
Avalia o da eficiência das várias fases de um sistema de tratamento de efluentes
José Ivan Vieira De Lima,Wilson Costa
Tecno-Lógica , 2011,
Abstract: O tratamento de efluentes pode ser realizado por processos físico-químicos e ou biológicos, que podem ser aeróbios e ou anaeróbios. A utiliza o de qualquer processo de tratamento de efluentes, geralmente objetiva a remo o da carga organica e, dependendo dos dispositivos utilizados, apresenta rendimentos diferentes. O objetivo deste trabalho foi de avaliar um sistema de tratamento de efluentes de origem doméstica que apresenta tratamento primário, secundário e auxiliar. O primário é realizado por um dispositivo que impede a entrada de material grosseiro e pelo desarenador, que retém o material inerte. O secundário, destinado a degrada o dos compostos organicos, é realizado pelo reator anaeróbio de manta de lodo. O processo auxiliar, é uma lagoa de polimento. A avalia o foi feita, através da determina o do pH, Oxigênio Consumido (OC/DQO), Demanda Bioquímica de Oxigênio (DBO), rela o DQO/DBO, Alcalinidade, ácidos Graxos Voláteis (AGV), Nitrogênio amoniacal, nitrato, Fósforo Total, Turbidez e Sólidos Sedimentáveis (SS). Os resultados mostraram, que o processo biológico utilizado é adequado, já que a rela o DQO/DBO é menor que 2,5, que o sistema foi capaz de remover matéria organica em termos de OC e DBO na ordem de 43,1 % e 44,8 % respectivamente e, que o teor de fósforo total na lagoa de polimento está elevado, o que pode ocasionar eutrofiza o. Abstract The treatment of the wastewater can be processedby either physical-chemical and or biological methods.Biological methods in turn can be divided into aerobic andanaerobic. The utilization anything process usually have forobjective to remove the organ matter and, the performance isvariable depending on the device utilized. The purpose of thepresent work is to evaluate the treatment wastewater system withprimary, secondary and auxiliary treatments. The primarytreatment consists of a dispositive that blockade bulky materialsand the sand excluder for removing the inert materials. Thesecondary, responsible for the organic charge elimination isrealized by up flow of an anaerobic sludge mantle filter. Theauxiliary treatment is a polishing pond. The evaluation was madethrough the determination of pH, Consumed Oxygen (CO/COD),Biochemical Oxygen Demand (BOD), COD/BOD relation, alkalinity, volatile fatty acids (VFA), total nitrogen, ammonium, nitrate, total phosphorus, turbidity and settable solids determination. The results showed that the biological process used is appropriate given that the ratio COD / BOD is less than 2.5, the system was capable of removing organic matter in terms of OC and BOD at the rates
ARCHETYPES OF CONSTRUCTED WETLANDS SYSTEMS FOR TREATMENT OF AQUICULTURE EFFLUENT = PROTóTIPOS DE SISTEMAS CONSTRUíDOS DE áREAS ALAGADAS PARA TRATAMENTO DE EFLUENTES DE PISCICULTURA
Rodrigo Cesar de Moraes Monteiro,Ana Kleiber Pessoa Borges,Samia Maria Tauk-Tornisielo,Roberto Naves Domingos
Holos Environment , 2008,
Abstract: The aquaculture is an activity that finishes causing eutrofization them water bodies in which its effluent one is launched, decurrent of the nutrition and prophylaxes used in its reservoirs. The components that cause greater problems are those that contain nitrogen and phosphorus. The management used in the aquiculture must be guided in such way to prevent the eutrofization and to provide treatment of effluent and water reuse. Constructed wetland system (CWS’s) has been efficient for treatment of waters, effluent and domestic and industrial sewer, being pertinent so that physical, chemical and biological processes occur similar as they happen in natural ecosystems. Initially some archetypes of CWS’s had been simulated, in laboratory scale, using 46 L reservoirs, with aeration system, being vegetated with a polyculture of aquatic macrophytes, for effluent treatment of tanks of Tilapia of the Nile creation. The analyzed types of support matrix had been: soil of cerrado area; soil plus brick fragments (1:1) (aggregate); soil plus brick fragments (3:1); and brick fragments. The results had demonstrated that CWS’s contend soil plus aggregate was efficient to treat the effluent one used in this study. After the stabilization of CWS’s, better efficiencies had been observed in the system only contend brick fragments or only soil, depending on the analyzed parameter. = A piscicultura é uma atividade que acarreta o processo de eutrofiza o nos corpos de água nos quais seu efluente é lan ado, decorrente da nutri o e profilaxias utilizadas em seus tanques de cria o. Os compostos que contribuem para o processo de eutrofiza o s o aqueles que contêm nutrientes, como nitrogênio e fósforo. Os manejos utilizados na piscicultura devem ser orientados de tal modo a se evitar o processo de eutrofiza o, e contemplar tratamentos dos efluentes. Sistemas construídos de áreas alagadas Cosntructed Wetland System - CWS’s têm mostrado eficiência quanto ao tratamento de águas, efluentes domésticos e industriais e efluentes de aqüicultura, demonstrando ser um meio eficiente para que ocorram os processos físicos, químicos e biológicos comuns aqueles de áreas alagadas naturais. Foram simulados alguns protótipos de CWS’s, em escala de laboratório, utilizando reservatórios de 46 L, com sistema de aera o ativa, fluxo vertical descendente, sendo vegetado com uma policultura de macrófitas aquáticas, para tratamento de efluente de tanques de cria o de Oreochromis niloticus (Tilápia do Nilo). Cada par de reservatórios foi preenchido com um dos quatro tipos de matriz suporte: solo de área
Efficiency of a constructed wetland for wastewaters treatment Eficiência de um "wetland" construído no tratamento de efluentes  [cached]
Fernanda Travaini-Lima,Lúcia Helena Sipaúba-Tavares
Acta Limnologica Brasiliensia , 2012,
Abstract: AIM: The limnological characteristics of three different inlets water of the constructed wetland were compared in terms of concentration data and loading rate data and evaluated the removal efficiencies of nutrients, solids, BOD5, chlorophyll-a and thermotolerant coliforms (TC) by the treatment system; METHODS: The constructed wetland, measuring 82.8 m2 and with detention time of 1 hour and 58 minutes in the rainy season and 2 hours and 42 minutes in the dry one, was provided with four species, Cyperus giganteus Vahl, Typha domingensis Pers., Pontederia cordata L. e Eichhornia crassipes (Mart.) Solms. The sampling sites evaluated in the dry (D) and rainy (R) seasons were: inlet water from aquaculture farm = IA; inlet channel of rainwater runoff = IR; inlet from UASB wastewater = IB; outlet wetland = OUT. The conductivity, pH, temperature, dissolved oxygen, alkalinity, BOD5, total soluble and dissolved solids, nitrogen, phosphorus, chlorophyll-a and TC were analyzed. Multivariate analyses, such as Cluster and Principal Components Analysis (PCA), were carried out to group sampling sites with similar limnological characteristics; RESULTS: In the PCA with the concentration data was retained 90.52% variability of data, correlating the inlet IB with high concentrations of conductivity, alkalinity, pH, TC, nutrients and solids. Regarding loading rate data, the PCA was retained 80.9% of the data's total variability and correlated the sampling sites IA D, IA R and OUT R with higher BOD5, chlorophyll-a, TDS, nitrate, nitrite, total-P, temperature, oxygen and water flow. The highest removal efficiencies rates occurred in the dry season, mainly in concentration, with 78% of ammonia, 95.5% of SRP, 94.9% of TSS and 99.9% of TC; CONCLUSIONS: The wetland was highly efficacious in the removal of nutrients, solids, BOD5, chlorophyll-a and TC, mainly during the dry season. The system restructuring to increase the detention time during the rainy season and a pre-treatment of UASB wastewater, can increase the retention of nutrients and solids by wetland. OBJETIVO: Comparar as características limnológicas de três diferentes entradas de água no "wetland" construído, com dados de concentra o e carga, e avaliar a eficiência de remo o de nutrientes, sólidos, DBO5, clorofila-a e coliformes termotolerantes (TC) pelo sistema de tratamento; MéTODOS: No "wetland" construído, com área total de 82.8 m2 e tempo de residência de 1 hora e 58 minutos na esta o chuvosa e 2 horas e 42 minutos na seca, foram utilizadas as espécies Cyperus giganteus Vahl, Typha domingensis Pers., Pontederia
EFFLUENT TREATMENT OF PAY-TO-FISH IN CONSTRUCTED WETLAND SYSTEM = TRATAMENTO DE EFLUENTES DE PESQUE-PAGUE EM SISTEMA CONSTRUíDO DE áREAS ALAGADAS  [cached]
Alison Lulu Bitar,Samia Maria Tauk-Tornisielo,Alexandre Augusto Oliveira Santos,Eleni Nadai Malagutti
Holos Environment , 2009,
Abstract: The use of efficient process and low cost for effluent despollution comes being intensely applied in the Europe and United States and, gradually, in other countries in the three last decades. This is the “Constructed Wetland Systems” (CWS).Considering this trend, this study it has as objective to verify the effectiveness of this effluent treatment type for fish-pay, located in the basin of the Corumbatai River. Prototypes were built simulating CWS with horizontal subsurface flow and hydraulic retention time (HRT) unbroken in 2 days; checking its efficiency with or without aquatic macrophytes as Salvinia sp and Eichhornia crassipes and/or aggregate and soil. For simulation of the fish-pays’ tanks, have been created Nile tilapia fish (Oreochromis niloticus) into the reservoir of 1,500 litres controlling certain environmental factors. Three treatments were used with three different replicas each and analyzed through regular collections. The highest efficiencies had been verified how much to the reduction of the parameters total alkalinity, nitrite, ammonia, total nitrogen, material in suspension, chemical oxygen demand (COD), apparent color and turbidity. To optimize the reduction of phosphorus there is a need of greater control of environmental factors to the system used. The most efficient treatment system was soil-containing filter combined with the aquatic macrophytes. = O uso de processo eficiente e de baixo custo para despolui o de efluentes vem sendo intensamente aplicado na Europa e Estados Unidos e, gradativamente, em outros países nas três últimas décadas. Trata-se dos sistemas construídos de áreas alagadas “Constructed Wetland Systems” (CWS). Considerando esta tendência, este estudo tem como objetivo verificar a eficiência deste tipo de tratamento para efluentes de pesque-pague, localizados na bacia do rio Corumbataí. Foram construídos protótipos simulando (CWS) de fluxo subsuperficial horizontal e tempo de reten o hidráulica (TRH) constante em 2 dias. Verificou-se sua eficiência com ou sem macrófitas aquáticas Salvinia sp e Eichhornia crassipes e/ou com agregados e solo. Para simula o dos tanques de pesque-pague, foram criados peixes Tilápias do Nilo (Oreochromis niloticus) em tanque de 1.500L e controlando determinados fatores ambientais. Foram usados três tratamentos diferentes, com três réplicas cada, analisados mediante coletas periódicas. As maiores eficiências foram verificada quanto à redu o dos parametros alcalinidade total, nitrito, am nia, nitrogênio total, material em suspens o, demanda química de oxigênio (DQO), cor aparente e t
pH AND TEMPERATURE IN AFFLUENTS AND EFFLUENTS OF BOVINE SLAUGHTERHOUSES IN GOIáS pH E TEMPERATURA DE AFLUENTES E EFLUENTES DE MATADOUROS FRIGORíFICOS DE BOVINOS EM GOIáS
César Augusto Garcia
Pesquisa Agropecuária Tropical , 2007, DOI: 10.5216/pat.v23i1.2631
Abstract: The pH and the temperature of 140 wastewater samples were analysed in two bovine slaughterhouses, only one of them had effluents treatment system. The conclusion was that the effluents treatment system interfered on pH and temperature. Foram analisados o pH e a temperatura de 140 amostras de água de afluentes e efluentes de dois matadouros frigoríficos através de potenci metro digital portátil e de term metro de coluna de mercúrio. Um dos frigoríficos possuía tratamento até a fase secundária (tratamento biológico), enquanto o outro n o dispunha de qualquer tipo de tratamento para seus efluentes. O frigorífico que dispunha de tratamento de efluentes apresentou águas servidas com pH mais alcalino que seus afluentes e os efluentes da outra indústria, além de temperaturas maiores que as de seus afluentes. O frigorífico que n o possuía sistema de tratamento de efluentes apresentou os mesmos com pH mais ácido e com temperaturas mais elevadas do que seus afluentes.
Possibilidade de utiliza o da irriga o com ossibilidade água residuária em torno das principais esta es de tratamento de efluentes da Regi o Metropolitana de Curitiba, Estado do Paraná, Brasil = Wastewater use potencial for irrigation in the metropolitan area of Curitiba, Paraná State, Brazil
Clodoveu Valdeni Trentin,Jorge Luiz Moretti de Souza
Acta Scientiarum : Agronomy , 2006,
Abstract: O presente trabalho consistiu no levantamento de parametros de qualidade dos efluentes e na realiza o de mapeamento dos solos ao redor das principais Esta es de Tratamento de Efluentes (ETEs) da Sanepar, na Regi o Metropolitana de Curitiba, visando analisar a possibilidade de irrigar culturas agrícolas com água residuária. Com base nos dados levantados e analisados, verificou-se que: as ETEs analisadas possuem boa eficiência no tratamento dos efluentes, mas ainda apresentam limites de qualidade fora do recomendado na literatura para uso na irriga o agrícola, principalmente a DBO; os solos Gleissolo, Organossolo e Neossolo existentes na regi o, por serem mal drenados, s o mais adequados para irriga o por inunda o, enquanto que os Argissolos, Cambissolos e Latossolos s o adequados às práticas da irriga o por aspers o e localizada; gr os e olerícolass o os grupos de culturas mais promissores para serem irrigados com águas residuárias na regi o das ETEs com potencial para explora o agrícola. The present work goal was to evaluate the wastewater use potential for irrigation in Curitiba metropolitan area, Paraná State, Brazil. In order to evaluate the potential for wastewater use, effluent quality from main Sanepar sewage sludge plants was determined as well as the major soil class near to each station. Wastewater analysis indicated that the sewage sludge plants have good effluent treatment efficiency, but not enough to reach the water standard quality required for agricultural irrigation, mainly due to high BOD. The major soil classes found in the low land area were Histosol andEntisol which are more adapted for flood irrigation, due to poor drainage soil capacity. While, Ultisol, Inceptisol, and Oxisol are found in high land area, and they are more appropriate for sprinkler and localized irrigation. Commercial grain and vegetable production are the more promising crop groups to be irrigated with wastewater in this region.
Physical-chemical and operational performance of an anaerobic baffled reactor (ABR) treating swine wastewater = Desempenho físico-químico e operacional de um reator anaeróbio compartimentado (RAC) como tratamento biológico preliminar de efluentes de suinocultura
Erlon Lopes Pereira,Cláudio Milton Montenegro Campos,Fabrício Moterani
Acta Scientiarum : Technology , 2010,
Abstract: Since hog raising concentrates a huge amount of swine manure in smallareas, it is considered by the environmental government organizations to be one of the most potentially pollutant activities. Therefore the main objective of this research was to evaluate by operational criteria and removal efficiency, the performance of a Anaerobic Baffled Reactor (ABR), working as a biological pre-treatment of swine culture effluents. The physical-chemical analyses carried out were: total COD, BOD5, total solids (TS), fix (TFS) and volatiles (TVS), temperature, pH, total Kjeldahl nitrogen, phosphorus, total acidity and alkalinity. The ABR unit worked with an average efficiency of 65.2 and 76.2%, respectively, concerning total COD and BOD5, with a hydraulic retention time (HRT) about 15 hours. The results for volumetric organic loading rate (VOLR), organic loading rate (OLR) andhydraulic loading rate (HLR) were: 4.46 kg BOD m-3 day-1; 1.81 kg BOD5 kg TVS-1 day-1 and 1.57 m3 m-3 day-1, respectively. The average efficiency of the whole treatment system for total COD and BOD5 removal were 66.5 and 77.8%, showing an adequate performancein removing the organic matter from swine wastewater. A suinocultura por ser uma atividade pecuária concentradora de dejetos em pequenas áreas é considerada, pelos órg os de gerência ambiental, como uma das atividades mais degradadoras do meio ambiente. Nesta pesquisa objetivou-se, por conseguinte, avaliar a utiliza o de um reator anaeróbio compartimentado (RAC), como unidade de prétratamento de um reator tipo UASB, em escala piloto, na adequa o ambiental dos efluentes de suinocultura, avaliando critérios operacionais e a eficiência. As análises físico-químicasrealizadas foram: DQOtotal, DBO5, sólidos totais (ST), fixos (SF) e voláteis (SV), temperatura, pH, nitrogênio total Kjeldahl, fósforo, acidez total e alcalinidade. A unidade RAC trabalhou com eficiência de 65,2 e 76,2% para a remo o de DQOtotal e DBO5, respectivamente, para o TDH médio de 15h. Os valores obtidos para a carga organicavolumétrica (COV), carga organica biológica (COB) e carga hidráulica (CH) foram de 4,46 kgDBO5 m-3 dia-1; 1,81 kg DBO5 kg SVT-1 dia-1 e 1,57 m3 m-3 dia-1, respectivamente. O sistema de tratamento proporcionou eficiências médias de remo o de 66,5 e 77,8% paraDQOtotal e DBO5, respectivamente, demonstrando adequada performance na remo o de material organico proveniente do efluente líquido da suinocultura.
Page 1 /100
Display every page Item


Home
Copyright © 2008-2017 Open Access Library. All rights reserved.