    Lee, S.H., Kim, M.J., Yoon, C.S., et al. (2012) Radiation Dose Reduction with the Adaptive Statistical Iterative Reconstruction (ASIR) Technique for Chest CT in Children: An Intra-Individual Comparison. European Journal of Radiology, 81, e938-e943.
    http://dx.doi.org/10.1016/j.ejrad.2012.06.013

has been cited by the following article:

  • TITLE: Comparison of CT Dose Reduction Algorithms in a Porcine Model
  • AUTHORS: Mohammed Nazir Khan, Idris Elbakri, Blair Henderson, Jeffrey Mottola, Azeez Omotayo
  • KEYWORDS: Computed Tomography, Dose Reduction, Iterative Reconstruction, Porcine, ASIR, VEO, FBP
  • JOURNAL NAME: Advances in Computed Tomography DOI: 10.4236/act.2015.44008 Dec 11, 2015
  • ABSTRACT: The present study utilized a porcine model for qualitative and quantitative assessment of the diagnostic quality of non-contrast abdominal computed tomography (CT) images generated by Adaptive Statistical Iterative Reconstruction (ASIR, GE Healthcare, Waukesha, Wisconsin, USA), Model-Based Iterative Reconstruction (GE company name VEO), and conventional Filtered back projection (FBP) technique. Methods: Multiple CT whole-body scans of a freshly euthanized pig carcass were performed on a 64-slice GE CT scanner at varying noise indices (5, 10, 15, 20, 30, 37, 40, 45), and with three different algorithms (VEO, FBP, and ASIR at 30%, 50%, and 70% levels of ASIR-FBP blending). Abdominal CT images were reviewed and scored in a blinded and randomized manner by two board-certified abdominal radiologists. The task was to evaluate the clarity of the images according to a rubric involving edge sharpness, presence of artifact, anatomical clarity (assessed at four regions), and perceived diagnostic acceptability. This amounted to seven criteria, each of which was graded on a scale of 1 to 5. A weighted formula was used to calculate a composite score for each scan. Results: VEO outperforms ASIR and FBP by an average of 0.5 points per the scoring system used (p < 0.05). Above a threshold noise index of 30, diagnostic acceptability is lost by all algorithms, and there is no diagnostic advantage to increasing the dose beyond a noise index of 10. Between a noise index of 25 - 30, VEO retains diagnostic acceptability, as opposed to ASIR and FBP which lose acceptability above noise index of 25. Conclusion: Model-based iterative reconstruction provides superior image quality and anatomical clarity at reduced radiation dosages, supporting the routine use of this technology, particularly in pediatric abdominal CT scans.