All Title Author
Keywords Abstract

Publish in OALib Journal
ISSN: 2333-9721
APC: Only $99

ViewsDownloads

Relative Articles

Electrochemical oxidation of niclosamide at a glassy carbon electrode and its determination by voltammetry

Electrochemical oxidation of niclosamide at a glassy carbon electrode and its determination by voltammetry

Electrochemical behavior of metribuzin on a glassy carbon electrode in an aqueous medium including quantitative studies by anodic stripping voltammetry

Evaluation of a nafion coated glassy carbon electrode for determination of paraquat by differential pulse voltammetry

Direct Electron Transfer of Hemoglobin on Manganese III Oxide-Ag Nanofibers Modified Glassy Carbon Electrode

ЕЛЕКТРОКАТАЛ ТИЧНЕ ПЕРЕТВОРЕННЯ ЕТАНОЛУ НА ДОПОВАНОМУ Л Т М ТА НАТР М Д ОКСИД МАНГАНОВОМУ ЕЛЕКТРОД Electro-catalytic conversion of ethanol doped with lithium and sodium manganese dioxide electrode Электрокаталитическое преобразования этанола в допированных литием и натрием диоксид марганцевому электроде

Determination of Silver(I) by Differential Pulse Voltammetry Using a Glassy Carbon Electrode Modified with Synthesized N-(2-Aminoethyl)-4,4'-Bipyridine

Electrochemical Behavior and the Determination of Omeprazole Using Glassy Carbon Electrode

Dithiooxamide Modified Glassy Carbon Electrode for the Studies of Non-Aqueous Media: Electrochemical Behaviors of Quercetin on the Electrode Surface

More...

PREPARATION OF MANGANESE DIOXIDE MODIFIED GLASSY CARBON ELECTRODE BY A NOVEL FILM PLATING/CYCLIC VOLTAMMETRY METHOD FOR H(2)0(2) DETECTION

DOI: 10.4067/S0717-97072009000400009

Keywords: manganese dioxide, film plating/cyclic voltammetry, glassy carbon electrode, electrocatalysis.

Full-Text   Cite this paper   Add to My Lib

Abstract:

manganese dioxide modified glassy carbon electrode (mn02/gc) was prepared by a novel film plating/cyclic voltammetry method for the determination of h202. a manganese film was first cathodically deposited on the surface of glassy carbon electrode from mncl2 solution at the potential of-1.4 v versus ag/ agcl (satd. kc1), and then a well defined manganese dioxide was deposited on the surface of glassy carbon electrode by cyclic voltammetry at potential range -0.6 ~ 0.6 v, scan rate 100 mv s-1 in 0.1 mol l71 naoh solution. the resulted modified electrode was characterized by cyclic voltammetry and scanning electron microscopy (sem), which showed excellent electrocatalytic activity for the oxidation of h202. the chronoamperometric detection of h202 was carried out at 0.6 v in phosphate buffer solution ph 7.38 containing 0.1 mol l71 kc1 and the linear relationship of response current on h202 concentration was obtained in the range from 4. ixl0~10 to lxl0~-mol l-1 with a minimum detectable concentration of 3xl0~10 mol l71 [s/n (signal noise ratio) = 3]. the response time of the electrode to achieve 95% of the steady-state current was < 2 s. no measurable reduction in analytical performance of the modified electrode was found by storing the electrode in ambient conditions for 30 days. this modified electrode has many advantages such as simple preparation procedure, remarkable catalytic activity, good reproducibility and long term stability of signal response during hydrogen peroxide oxidation. the deposition of manganese dioxide on the surface of gc appears to be a highly efficient method for the development of a new class of sensitive, stable and reproducible hydrogen peroxide electrochemical sensor.

Full-Text

comments powered by Disqus