All Title Author
Keywords Abstract

Publish in OALib Journal
ISSN: 2333-9721
APC: Only $99

ViewsDownloads

Relative Articles

Efecto de Distintos Niveles de Poda y Reposición Hídrica sobre el Crecimiento Vegetativo, Rendimiento y Composición de Bayas en Vides cv. Cabernet Sauvignon

Model Validation for Estimating the Leaf Stomatal Conductance in cv. Cabernet Sauvignon Grapevines

Avalia o da cv. Cabernet Sauvignon para elabora o de vinho tinto

Efecto de Distintos Niveles de Poda y Reposición Hídrica sobre el Crecimiento Vegetativo, Rendimiento y Composición de Bayas en Vides cv. Cabernet Sauvignon Effect of Different Levels of Pruning and Water Application on Vegetative Growth, Yield and Berry Composition in Grapes cv. Cabernet Sauvignon

Avalia??o da cv. Cabernet Sauvignon para elabora??o de vinho tinto

Photosynthesis and cell respiration modulated by water deficit in grapevine (Vitis vinifera L.) cv. Cabernet Sauvignon

DESARROLLO DE MODELOS PREDICTIVOS DE FENOLOGíA Y EVOLUCIóN DE MADUREZ EN VID PARA VINO CV. CABERNET SAUVIGNON Y CHARDONNAY Development of models for predicting phenology and evolution of maturity in cv. Cabernet Sauvignon and Chardonnay grapevines

Evaluation of a model to Simulate Net Radiation Over a Vineyar cv. Cabernet Sauvignon

EFECTOS DE LA RESTRICCIóN DEL RIEGO EN DISTINTOS PERíODOS DE DESARROLLO DE LA VID CV. CABERNET SAUVIGNON SOBRE PRODUCCIóN Y CALIDAD DEL VINO Effects of restricted irrigation at different stages of development of Cabernet Sauvignon grapes on production and wine quality

DESARROLLO DE MODELOS PREDICTIVOS DE FENOLOGíA Y EVOLUCIóN DE MADUREZ EN VID PARA VINO CV. CABERNET SAUVIGNON Y CHARDONNAY

More...

Model Validation for Estimating the Leaf Stomatal Conductance in cv. Cabernet Sauvignon Grapevines Validación de un modelo para estimar la conductancia estomática de hojas en vides cv. Cabernet Sauvignon.

Keywords: modelo A-g s , fotosíntesis , conductancia del mesófilo , potencial hídrico del xilema , análisis de sensibilidad , A-g s model , photosynthesis , mesophyll conductance , stem water potential , sensitivity analysis

Full-Text   Cite this paper   Add to My Lib

Abstract:

The coupled model of assimilation and stomatal conductance (A-g s) was evaluated to estimate leaf stomatal conductance of a drip-irrigated vineyard (Vitis vinifera L. cv. Cabernet Sauvignon) located in the Pencahue Valley (35o22’ S, 71°47’ W, 150 m.a.s.l.), Maule Region, Chile, during the 2003-2004 and the 2004-2005 growing seasons. Additionally, a calibration of the three parameters mesophyll conductance (g m), maximum specific humidity (Dmax) and coupled factor (f0) was applied on vines growing in 35 L pots. An infrared gas analyzer was used to calibrate and evaluate the A-g s which allowed simultaneous measuring of the leaf net CO2 assimilation (A) and stomatal conductance (g s) in 2 to 3 h intervals of time. The calibration indicated that the g m,, Dmax and f0 values were 1.15 mm s-1, 52.31 g kg-1 and 0.90, respectively. The validation in the drip-irrigated vineyard indicated that the A-g s model was able to estimate the leaf stomatal conductance with a root mean square error (RMSE) of 0.05 mol m-2 s-1, model efficiency of 61% and agreement index of 90%. The sensitivity analysis indicated that the A-g s model is affected considerably by the g m, Dmax and f0 parameterization. Validación de un modelo para estimar la conductancia estomática de hojas en vides cv. Cabernet Sauvignon. El modelo acoplado de asimilación neta y conductancia estomática (A-g s) fue evaluado para estimar la conductancia estomática de hojas (g s) de un vi edo regado por goteo (Vitis vinifera L. cv. Cabernet Sauvignon) ubicado en el Valle de Pencahue (35o22’ S; 71o47’ O; 150 m.s.n.m.), Región del Maule, Chile, durante las temporadas 2003-2004 y 2004-2005. Además, se realizó una calibración de la conductancia del mesófilo (g m), valor máximo de humedad específica a saturación (Dmax) y el factor acoplado (f0) en vides creciendo en maceteros de 35 L. Para calibrar y evaluar el modelo A-g s se utilizó un analizador infrarrojo de gases, el cual permitió medir simultáneamente la asimilación neta (A) y la conductancia estomática (g s) en intervalos de tiempo de 2 a 3 h. La calibración indicó que los valores de g m, Dmax y f0 fueron de 1,15 mm s-1; 52,31 g kg-1 y 0,90 respectivamente. La validación en el vi edo regado por goteo mostró que el modelo A-g s fue capaz de estimar la conductancia estomática con una raíz del cuadrado medio del error (RMSE) de 0,05 mol m-2 s-1, una eficiencia del modelo de 61% y un índice de acuerdo de 90%. El análisis de sensibilidad indicó que el modelo es considerablemente afectado por la parametrización de g m, Dmax y f0.

Full-Text

comments powered by Disqus